Beta
176151

Evaluation of sigma metric approach for monitoring the performance of automated analyzers in hematology unit of alexandria main university hospital

Article

Last updated: 26 Dec 2024

Subjects

-

Tags

-

Abstract

• The dependence of patient management on laboratory data raised the requirement for ensuring the quality of this service.
• -Sigma-metric offers a quantitative framework for evaluating process performance in clinical laboratories.
AIM OF THE WORK
• This study aimed to evaluate the analytical performance of automated analyzers in hematology unit of Alexandria Main University Hospital using sigma metric approach.
MATERIALS AND METHODS
Quality control data were collected for 6 months and Sigma value was calculated from hematology analyzers SYSMEX (XN 1000, XT 1800i), ADVIA (2120i, 2120) and coagulation analyzers SYSMEX CA 1500 (3610, 6336).
RESULTS
• For the normal control level, satisfactory mean sigma value ≥ 3 was observed for all of the studied parameters by all analyzers.
• For the high control level, Red blood cell count by ADVIA 2120, and hematocrit by ADVIA (2120i and 2120) performed poorly with a mean sigma value < 3.
• For the low control level, Red blood cell count by ADVIA (2120i and 2120), hemoglobin by ADVIA 2120, hematocrit by ADVIA (2120i and 2120) and SYSMEX XN 1000, Platelet count by the SYSMEX XT 1800i, also performed poorly with a mean sigma value < 3.
• Satisfactory mean sigma value of ≥ 3 was observed for Prothrombin time and activated partial thromboplastin time for both normal and pathological control levels and analyzers.

DOI

10.21608/alexpo.2021.79387.1175

Keywords

Sigma metric, Quality, Clinical laboratory

Authors

First Name

Nihal

Last Name

Abdellatif

MiddleName

Mahmoud

Affiliation

Department of chemical and clinical pathology, alexandria university egypt

Email

nihalmahmoud10@gmail.com

City

Alexandria

Orcid

-

Volume

3

Article Issue

2

Related Issue

28063

Issue Date

2021-06-01

Receive Date

2021-06-06

Publish Date

2021-06-01

Page Start

57

Page End

58

Online ISSN

2682-2636

Link

https://alexpos.journals.ekb.eg/article_176151.html

Detail API

https://alexpos.journals.ekb.eg/service?article_code=176151

Order

126

Type

Preliminary preprint short reports of original research

Type Code

1,426

Publication Type

Journal

Publication Title

ALEXMED ePosters

Publication Link

https://alexpos.journals.ekb.eg/

MainTitle

Evaluation of sigma metric approach for monitoring the performance of automated analyzers in hematology unit of alexandria main university hospital

Details

Type

Article

Created At

23 Jan 2023