Background: Pulmonary Embolism PE is a potentially fatal disorder and the third most common acute cardiovascular disease, after myocardial infarction and stroke. In current clinical practice Lung Ventilation / Perfusion Scintigraphy is mainly used to exclude PE andComputed Tomography Pulmonary Angiography CTPA has now been widely accepted as the standard test for the diagnosis of acute pulmonary emboli. Aim of work: to compare the performance of dual energy
computed tomography lung perfusion and ventilation/perfusion scintigraphy in the detection of pulmonary embolism.
Patients and Methods: Twenty-six patients with suspected acute pulmonary thromboembolism underwent both DECT and SPECT V/Q scanning. Nine of these patients were females and 17 were males. Average age of the patients was 55.2 years. The diagnostic value of DECT lung perfusion imaging was assessed regarding V/Q SPECT as standard of reference. Diagnostic accuracy was calculated per patient and per segment using standard contingency tables. Chi-square test
and Receiver operating characteristic curve were to assess sensitivity, specificity, positive predictive value, negative predictive value and accuracy taking SPECT as a gold standard. Results: acute PE was diagnosed in 19 patients based on DECT findings and in 16 patients based on nuclear medicine findings. Concordant positive diagnoses were made in 16 patients. Two patients had segmental and subsegmental perfusion defect in both imaging modalities. Due to a correlative ventilation defect (matched V/Q SPECT), this finding was rated as being consistent with prior PE in nuclear medicine imaging. However, CTPA findings suggested acute PE due to an intraluminal filling defect in the supplying segmental
artery that showed a typical configuration of a recently developed embolus.One patient result was false negative with homogeneous perfusion in both DE iodine mapping and SPECT, there was nonocclusive embolus at the segmental level outlined by contrast material. Seven cases showed negative diagnoses, i.e. no evidence of PE. Sensitivity/specificity for the detection of perfusion defects were thus 82.9% and 100% by DECT iodine perfusion mapping per segment and
combined DE-CTPA had a sensitivity/specificity of 100%/100% for detection of acute PE per patient. Conclusion: DECT is the test of choice for the evaluation of suspected PE due to its availability, speed, high accuracy, and ability to identify alternative diagnoses.

DOI

10.21608/asmj.2020.125666

Keywords

Lung Perfusion, Scintigraphy, Ventilation, pulmonary embolism

Authors

First Name

Khaled

Last Name

Abdelghany

MiddleName

Ahmed Abuzeid

Affiliation

Department of radiology and nuclear medicine Ain Shams University and Department of medical imaging Al-Adan hospital Kuwait.

Email

-

City

-

Orcid

-

First Name

Noha

Last Name

Osman

MiddleName

Mohamed

Affiliation

Department of radiology and nuclear medicine Ain Shams University and Department of medical imaging Al-Adan hospital Kuwait.

Email

-

City

-

Orcid

-

First Name

Eman

Last Name

Geneidi

MiddleName

Ahmed Shawky

Affiliation

Department of radiology and nuclear medicine Ain Shams University and Department of medical imaging Al-Adan hospital Kuwait.

Email

-

City

-

Orcid

-

First Name

Hala

Last Name

Abou Senna

MiddleName

Mahmoud

Affiliation

Department of radiology and nuclear medicine Ain Shams University and Department of medical imaging Al-Adan hospital Kuwait.

Email

-

City

-

Orcid

-

First Name

Ahmed

Last Name

Nasr

MiddleName

Mohamed Sabry

Affiliation

Department of radiology and nuclear medicine Ain Shams University and Department of medical imaging Al-Adan hospital Kuwait.

Email

-

City

-

Orcid

-

First Name

Ebaa

Last Name

Hassanein

MiddleName

Ahmed Mohamed

Affiliation

Department of radiology and nuclear medicine Ain Shams University and Department of medical imaging Al-Adan hospital Kuwait.

Email

-

City

-

Orcid

-

First Name

Sherine

Last Name

Sharara

MiddleName

Mohamed

Affiliation

Department of radiology and nuclear medicine Ain Shams University and Department of medical imaging Al-Adan hospital Kuwait.

Email

-

City

-

Orcid

-

Volume

71

Article Issue

2

Related Issue

18820

Issue Date

2020-06-01

Receive Date

2020-11-26

Publish Date

2020-06-01

Page Start

399

Page End

410

Print ISSN

0002-2144

Online ISSN

2735-3540

Link

https://asmj.journals.ekb.eg/article_125666.html

Detail API

https://asmj.journals.ekb.eg/service?article_code=125666

Order

13

Type

Original Article

Type Code

1,311

Publication Type

Journal

Publication Title

Ain Shams Medical Journal

Publication Link

https://asmj.journals.ekb.eg/

MainTitle

COMPARISON OFDUAL ENERGY CT LUNG PERFUSION VERSUS LUNG VENTILATION/PERFUSION SCINTIGRAPHY IN PULMONARY EMBOLISM

Details

Type

Article

Created At

22 Jan 2023