ENHANCING THE SAFETY OF EPOXY FLOOR MATERIALS BY USING COPPER CHIP
Last updated: 04 Jan 2025
10.21608/jest.2022.231182
Epoxy, Static friction coefficient, Electrostatic charge, water, Copper chip
A. H.
El-Abd
Dept. of Mechanical Power Engineering El-Arish High Institute of Engineering and Technology, Ministry of Higher Education, Egypt.
A. M.
Samy
Dept. of Production Engineering & Mechanical Design, Faculty of Engineering, Minia University, Egypt.
A. K.
Ameer
Dept. of Production Engineering & Mechanical Design, Faculty of Engineering, Minia University, Egypt.
19
2
33098
2022-04-01
2022-02-22
2022-04-01
88
98
2090-5882
2090-5955
https://jest.journals.ekb.eg/article_231182.html
https://jest.journals.ekb.eg/service?article_code=231182
8
Original Article
1,211
Journal
Journal of the Egyptian Society of Tribology
https://jest.journals.ekb.eg/
ENHANCING THE SAFETY OF EPOXY FLOOR MATERIALS BY USING COPPER CHIP
Details
Type
Article
Created At
22 Jan 2023