Abstract

This paper presents an analytical  study of the resultant m.m.f. distributions in the air-gap of a divided-winding-rotor synchronous generator. For linear analysis, the principle of superposition can be applied to obtain these distributions graphically. The study makes use of the no-load field control factors to obtain the actual per-unit maximum values of both field components while the resultant field is shifted in steps w.r.t. the rotor. The obtained wave forms exhibits the possibility of summarizing then in a group of representative wave forms which enable us to study the effect of shift-angle, as well as well as the pole winding spread , on the resultant m.m.f. the m.m.f. distributions obtained experimentally, are compared with those analytically obtained. The results show that they are in good agreement. The conditions required to simulate the conventional field distribution by a divided-winding-rotor are stated and discussed.

DOI

10.21608/bfemu.1979.183193

Authors

First Name

Hassan

Last Name

Abou-Tabl

MiddleName

Ali Hassan

Affiliation

Assistant Professor, Electrical Power & Machines Department, Faculty of Engineering, Mansoura University, Mansoura, Egypt.

Email

-

City

Mansoura

Orcid

-

Volume

4

Article Issue

1

Related Issue

26312

Issue Date

1979-06-01

Receive Date

1979-04-16

Publish Date

1978-06-01

Page Start

92

Page End

104

Print ISSN

1110-0923

Online ISSN

2735-4202

Link

https://bfemu.journals.ekb.eg/article_183193.html

Detail API

https://bfemu.journals.ekb.eg/service?article_code=183193

Order

31

Type

Research Studies

Type Code

1,205

Publication Type

Journal

Publication Title

MEJ. Mansoura Engineering Journal

Publication Link

https://bfemu.journals.ekb.eg/

MainTitle

-

Details

Type

Article

Created At

22 Jan 2023