Beta
171461

Effect of Air Injection Method on the Performance of Air-Lift Pump.

Article

Last updated: 04 Jan 2025

Subjects

-

Tags

Mechanical Power Engineering

Abstract

 Different methods of air injection into the riser of an air-lift pump were experimentally tested. Measurements were carried out on a riser tube (50.8 mm diameter and 2400 mm long) at different ratios of 
and various values of (1.33, 1.89 and 2.81) to submergence lift injection pressure (2, 3 and 4 Kg/cm2). Both water flow rate and pump efficiency are shown against air flow rate calculated at STP different methods of injection.
A marked effect was found on the pump performance when operated with different types of injectors. This effect is attributed to the fact that initial bubble size and effect is attributed to the fact that riser and consequently the pump efficiency.

DOI

10.21608/bfemu.2021.171461

Authors

First Name

H.

Last Name

Mansour

MiddleName

-

Affiliation

Mechanical Power Engineering Department., Faculty of Engineering., El-Mansoura University., Mansoura., Egypt.

Email

mnhsaadanyh@yahoo.com

City

Mansoura

Orcid

-

First Name

M.

Last Name

Khalil

MiddleName

-

Affiliation

Mechanical Power Engineering Department., Faculty of Engineering., Alexandria University., Alexandria., Egypt.

Email

-

City

Alexandria

Orcid

-

Volume

15

Article Issue

2

Related Issue

24852

Issue Date

1990-12-01

Receive Date

1990-10-23

Publish Date

2021-05-23

Page Start

107

Page End

118

Print ISSN

1110-0923

Online ISSN

2735-4202

Link

https://bfemu.journals.ekb.eg/article_171461.html

Detail API

https://bfemu.journals.ekb.eg/service?article_code=171461

Order

22

Type

Research Studies

Type Code

1,205

Publication Type

Journal

Publication Title

MEJ. Mansoura Engineering Journal

Publication Link

https://bfemu.journals.ekb.eg/

MainTitle

Effect of Air Injection Method on the Performance of Air-Lift Pump.

Details

Type

Article

Created At