Subjects
-Tags
-Abstract
Background: Range of Motion (ROM) of the joint is one of the elements that affect musculoskeletal system function. A valid and reliable method should be used to measure and record the ROM measurements. Purpose: This study was conducted to test the criterion related validity and the intra-rater reliability of rebee wearable sensor in measuring Active Range of Motion (AROM) of knee joint flexion and extension . Methods: Forty normal participant's age ranged from 30 to 45 years and their Body Mass Index (BMI) from 19 to 25 kg/m2 involved in one group. The Digital Goniometer and rebee wearable sensor were utilized to measure AROM of knee joint flexion and extension. Results: showed that measurement of AROM of the knee joint flexion with rebee sensor was significantly correlated with the measurement of digital goniometer for AROM of knee joint Flexion (p-value=0.001).The intra-rater reliability using the Intra-class Correlation Coefficient (ICC) showed that there was a high reliability of rebee wearable sensor in measurement the AROM of knee joint Flexion ,but there was a low reliability of rebee wearable sensor in measurement the AROM of knee joint Extension when compared with measurements for AROM of knee joint using digital goniometer. Conclusions: Rebee wearable sensor is a valid instrument for measurement of AROM of knee joint flexion, but not valid for measurement of AROM of knee joint extension.Regarding reliability rebee wearable sensor has high reliability of measurement of AROM of knee joint flexion, but low reliability for measurement of AROM of knee joint extension.
DOI
10.21608/ejpt.2022.119941.1071
Keywords
Digital Goniometer, Rebee wearable sensor, Reliability, Validity, Active range of motion of knee joint
Authors
MiddleName
-Affiliation
Basic science department, Faculty of Physical Therapy , Pharos University , Alexandria , Egypt
Email
ahmed.saleh@pua.edu.eg
Orcid
-Affiliation
Basic science department,Faculty of Physical Therapy, Cairo University, Giza, Egypt.
Email
dr.wadida.hassan@gmail.com
Orcid
-Affiliation
Basic science department, Faculty of Physical Therapy, Cairo University, Giza , Egypt.
Email
raniareda22@hotmail.com
City
-Orcid
-Link
https://ejpt.journals.ekb.eg/article_274367.html
Detail API
https://ejpt.journals.ekb.eg/service?article_code=274367
Publication Title
Egyptian Journal of Physical Therapy
Publication Link
https://ejpt.journals.ekb.eg/
MainTitle
VALIDITY AND RELIABILITY OF REBEE WEARABLE SENSOR IN MEASUREMENT OF KNEE JOINT RANGE OF MOTION