79204

Plasma arc versus holgen light curing of ceramic brackets

Article

Last updated: 04 Jan 2025

Subjects

-

Tags

-

Abstract

Bond strength and debonding characteristics of plasma arc curing light compared to halogen curing light when used to bond mechanical base retention ceramic brackets were tested in this study. Brackets were bonded to 50 extracted human maxillary premolars with a composite adhesive and they were divided into two equal groups. A curing time of 3 seconds was used for curing with the plasma arc light, and 20 seconds per bracket with the halogen light. Thermocycling was performed to simulate oral cavity conditions. For shear bond testing; Debonding of 15 brackets from each group was performed on a universal testing machine. There was no significant difference in the shear bond strength of brackets bonded by the two lights. Bond strength was 9.65 ±3.1 MPa for plasma arc curing light and 9.35 ± 2.33 MPa for the halogen light. In both groups the shear bond strength fell in the clinically acceptable range. 10 Brackets from each group were debonded using the debonding plier to test the debonding chraracteristics. Brackets consistently debonded at the bracket-adhesive interface with both types of curing lights. A reasonable amount of composite was always left on the enamel surface thus protecting enamel from detachments. These results indicate that the plasma arc light with a 3 second curing time can be used with mechanical retention base polycrystalline ceramic brackets to produce acceptable bond strength and a safe pattern for bracket debonding. Shear bond strength and ARI score values were comparable to halogen light curing which requires longer curing time.

DOI

10.21608/eos.2008.79204

Keywords

bonding, Ceramic brackets, halogen, plasma arc, curing light

Authors

First Name

Nadia

Last Name

El Harouni

MiddleName

M

Affiliation

Department of Orthodontic, Faculty of Dentistry, Alexandria University, Alexandria, Egypt

Email

-

City

-

Orcid

-

Volume

34

Article Issue

December 2008

Related Issue

11827

Issue Date

2008-12-01

Receive Date

2008-08-07

Publish Date

2008-12-01

Page Start

31

Page End

43

Print ISSN

1110-435X

Online ISSN

2812-5258

Link

https://eos.journals.ekb.eg/article_79204.html

Detail API

https://eos.journals.ekb.eg/service?article_code=79204

Order

3

Type

Original Article

Type Code

1,120

Publication Type

Journal

Publication Title

Egyptian Orthodontic Journal

Publication Link

https://eos.journals.ekb.eg/

MainTitle

Plasma arc versus holgen light curing of ceramic brackets

Details

Type

Article

Created At

22 Jan 2023