Beta
67335

PREDICTION OF THE FLOW FIELD IN VENTILATED ROOMS USING DIFFERENT TURBULENCE MODELS

Article

Last updated: 25 Dec 2024

Subjects

-

Tags

-

Abstract

This paper utilizes four turbulence models to predict the airflow field inside ventilated rooms. These models are namely the standard k–ε, RNG based k–ε, Low-Reynolds number and extended k-ε (Chen-Kim) models. The computational fluid dynamics (CFD) model is used to solve the basic equations of mass and momentum conservation in the primitive form together with the equations of turbulence model.  A model room is used to obtain some flow characteristics such as velocity and turbulent kinetic energy distributions along the flow field. To test the ability of different turbulence models for predicting the airflow field, the numerical results from the proposed models are compared with the published experimental results. To extra validation, a suitable room with inlet and outlet openings of air is designed and fabricated to obtain the velocity distribution. Also, numerical findings are compared to the measured results of vertical velocity distribution inside ventilated rooms. Comparisons declare that the extended standard k-ε (Chen-Kim) model can be used to predict the airflow field inside closed rooms equipped with forced ventilation systems more accurately when compared to other different turbulence models.

DOI

10.21608/erjm.2010.67335

Keywords

Room Ventilation, Turbulence models, Numerical simulation

Authors

First Name

T. I.

Last Name

Sabry

MiddleName

-

Affiliation

Mechanical Power Engineering Department, Faculty of Engineering, Minoufiya University, Shebin El-kom, Egypt

Email

-

City

-

Orcid

-

First Name

N. H.

Last Name

Mahmoud

MiddleName

-

Affiliation

Mechanical Power Engineering Department, Faculty of Engineering, Minoufiya University, Shebin El-kom, Egypt

Email

-

City

-

Orcid

-

First Name

A. A.

Last Name

Abdel-Hamied

MiddleName

-

Affiliation

Mechanical Power Engineering Department, Faculty of Engineering, Minoufiya University, Shebin El-kom, Egypt

Email

-

City

-

Orcid

-

First Name

A. A.

Last Name

Hussien

MiddleName

-

Affiliation

Mechanical Power Engineering Department, Faculty of Engineering, Minoufiya University, Shebin El-kom, Egypt

Email

-

City

-

Orcid

-

Volume

33

Article Issue

4

Related Issue

10169

Issue Date

2010-10-01

Receive Date

2020-01-02

Publish Date

2010-10-01

Page Start

333

Page End

343

Print ISSN

1110-1180

Online ISSN

3009-6944

Link

https://erjm.journals.ekb.eg/article_67335.html

Detail API

https://erjm.journals.ekb.eg/service?article_code=67335

Order

3

Type

Original Article

Type Code

1,118

Publication Type

Journal

Publication Title

ERJ. Engineering Research Journal

Publication Link

https://erjm.journals.ekb.eg/

MainTitle

PREDICTION OF THE FLOW FIELD IN VENTILATED ROOMS USING DIFFERENT TURBULENCE MODELS

Details

Type

Article

Created At