Abstract

Introduction: Primary stability and bone quality are key factors in implant success in early stages of placement while osseointegration comes further on.

Objectives: The aim of this study was to compare the effect of osseodensification on peri-implant strain during functional loading of a 4-unit monolithic zirconia bridge as well as its effect on primary stability and insertion torque.

Materials and Methods: Sixteen IS-II active implants were used in this study, the implants were divided into 2 groups. Group (A) were placed in conventionally drilled osteotomy sites with progressive subtractive enlargement and Group (B) were placed in osseo-densified osteotomy sites. All implants were inserted in unicortical polyurethane test blocks mimicking medium quality bone while recording insertion torque and implant stability quotient (ISQ) using Osstell for all implants. Each block contained two parallel implants carrying a 4-unit fixed partial denture (FPD). FPD were cemented then thermocycled for 5000/cycle and mechanically loaded at 100N, 2.5×10*5 cycles. A load of 400N and 600N and 800N was applied at connector areas in FPD. Strain gauges were connected to strain meter to record the peri-implant strain for both implants in all groups.

Results: Regarding insertion torque and peri-implant insertion torque strain Group (A) had significantly lower values than group B (p < 0.05) while insignificant Osstell values. Concerning peri-implant strain after loading group A had significantly higher strain values than Group (B) (p < 0.05).

Conclusions: Osseodensification drilling protocol increased insertion torque values and peri-implant insertion torque strain in comparison to conventional drilling protocol while decreasing peri-implant strain after loading.

DOI

10.21608/adjalexu.2021.39282.1095

Keywords

osseodensification, primary stability, Implants, in Vitro

Authors

First Name

Abdulla

Last Name

Abu Ghonaim

MiddleName

Ali

Affiliation

Pharos University

Email

dr.abdulla.ghonaim@gmail.com

City

Alexandria

Orcid

-

First Name

Amal

Last Name

Ezz el dein

MiddleName

-

Affiliation

Dental biomaterial, Alexandria university, Alexandria, Egypt

Email

amal.ezzeldin@pua.edu.eg

City

-

Orcid

-

First Name

Samir

Last Name

Bakry

MiddleName

Ibrahim

Affiliation

Professor of Fixed prosthodontics, Faculty of Dentistry, Alexandria University, Alexandria, Egypt.

Email

samirbakry@gmail.com

City

-

Orcid

-

Volume

46

Article Issue

3

Related Issue

28992

Issue Date

2021-12-01

Receive Date

2020-10-09

Publish Date

2021-12-01

Page Start

143

Page End

150

Print ISSN

1110-015X

Online ISSN

2536-9156

Link

https://adjalexu.journals.ekb.eg/article_185119.html

Detail API

https://adjalexu.journals.ekb.eg/service?article_code=185119

Order

28

Type

Original Article

Type Code

1,057

Publication Type

Journal

Publication Title

Alexandria Dental Journal

Publication Link

https://adjalexu.journals.ekb.eg/

MainTitle

COMPARATIVE EVALUATION OF OSSEODENSIFICATION EFFECT ON PERI-IMPLANT STRAIN WHILE LOADING A FOUR UNIT CERAMIC FIXED PARTIAL DENTURE (IN VITRO STUDY)

Details

Type

Article

Created At

22 Jan 2023