Abstract

Introduction: A well-constructed two-implant-assisted mandibular overdenture can be a successful treatment option for completely edentulous patients as it helps improving the oral function and patient satisfaction through elimination of the fear of dislodgment during speech or mastication. Various attachment systems can be used for retaining mandibular overdentures such as bar, ball and socket, OT equator and locators. A new attachment system with metal to metal interface named Titach has evolved. During mastication, loads are transferred to alveolar bone surrounding the implants.
Objectives: This study was done to compare the stress transmitted to peri-implant tissues of implant-assisted mandibular overdenture using two different attachment designs; Titach attachment and locator attachment.
Materials and methods: A completely edentulous epoxy resin mandibular model was used in which two parallel dental implants were inserted at the canine region bilaterally. Sixteen mandibular implant-assisted overdentures were constructed forming two groups; each with different attachment design. Group I received 8 pairs of Titach attachment, while group II received 8 pairs of locator attachment. The difference in stress distribution was measured using strain gauges and compared between the two studied groups. Vertical load and oblique load (30o and 45o) of 50 and 100 N using the universal testing machine were applied bilaterally on the central occlusal fossae of mandibular first molars.
Results:There was no significant difference between group I and II upon application of vertical loading 50, 100N and 30o oblique loading 50 N. However, group I showed lower strain values upon application of 30o oblique loading 100N, 45o oblique loading 50N and 100N.
Conclusions: Titach attachment with metal to metal interface showed less strain values with favourable stress distribution when compared to zest anchor locator attachment with nylon interface for implant-assisted mandibular overdenture.

DOI

10.21608/adjalexu.2020.79970

Keywords

implant-assisted overdenture, locator, Titach, strain gauges

Authors

First Name

Rania

Last Name

Ramadan

MiddleName

E.

Affiliation

Demonstrator of Removable prosthodontics, Faculty of Dentistry, Alexandria University.

Email

raniaelsayed392@gmail.com

City

-

Orcid

-

First Name

Faten

Last Name

Mohamed

MiddleName

S.

Affiliation

Professor of Removable Prosthodontics, Faculty of Dentistry, Alexandria University.

Email

-

City

-

Orcid

-

First Name

Mohamed

Last Name

Gepreel

MiddleName

A.

Affiliation

Associate Professor of Material Science and Engineering, School of Innovative Design Engineering, Egypt- Japan University of Science and Technology (E-Just).

Email

-

City

-

Orcid

-

Volume

45

Article Issue

1

Related Issue

12002

Issue Date

2020-04-01

Receive Date

2020-04-01

Publish Date

2020-04-01

Page Start

106

Page End

111

Print ISSN

1110-015X

Online ISSN

2536-9156

Link

https://adjalexu.journals.ekb.eg/article_79970.html

Detail API

https://adjalexu.journals.ekb.eg/service?article_code=79970

Order

18

Type

Original Article

Type Code

1,057

Publication Type

Journal

Publication Title

Alexandria Dental Journal

Publication Link

https://adjalexu.journals.ekb.eg/

MainTitle

-

Details

Type

Article

Created At

22 Jan 2023