Abstract

INTRODUCTION: Mechanical overload is thought to be one of the major causes of implant complications. The addition of micro threads increase linear length of coronal implant surface available for biologic width and allows some stress transfer and relieve the crestal stress and strain concentration in the coronal region. OBJECTIVES: Was to compare the influence of occlusal loading location on the strain developed around implants with two different crest module designs. MATERIALS AND METHODS: Ten Polyurethane test blocks in which implants were fixed at the maxillary left first premolar area. Specimens were divided into two parallel groups (n=5), Group (I) -implants, with micro threads, Group (II) implants with wide-groove threads. Strain gauges were connected to a strain meter to record the developed strain. A universal testing machine was used for load application up to 100 N. The data were statistically analyzed (p≤0.05). RESULTS: Group I exhibited the lower mean micro-strain values (260.0 ± 192.6 µε) than Group II (513.2 ± 108.2 µε).There was statistically significant difference between both groups(p > 0.05). CONCLUSIONS: Crest module designs affected the stress pattern induced around dental implants

DOI

10.21608/adjalexu.2018.57785

Keywords

Implant, Crest module, Micro threads, Macro threads, Strain gauge

Authors

First Name

Marwan A.

Last Name

Aggag

MiddleName

-

Affiliation

Instructor at Fixed Prosthodontics Department, Faculty of Dentistry, Pharos University in Alexandria, Egypt

Email

-

City

-

Orcid

-

First Name

Yousreya A.

Last Name

Shalaby

MiddleName

-

Affiliation

Professor of Fixed Prosthodontics, Department of Conservative Dentistry, Faculty of Dentistry, Alexandria University, Egypt

Email

-

City

-

Orcid

-

First Name

Mohammed S.

Last Name

Nassif

MiddleName

-

Affiliation

Associate Professor of Dental Biomaterials, Department of Dental Biomaterials, Faculty of Dentistry, Ain Shams University, Egypt.

Email

-

City

-

Orcid

-

First Name

Amir S.

Last Name

Azer

MiddleName

-

Affiliation

Lecturer of Fixed Prosthodontics, Department of Conservative Dentistry, Faculty of Dentistry, Alexandria University, Egypt.

Email

-

City

-

Orcid

-

Volume

43

Article Issue

3

Related Issue

8736

Issue Date

2018-12-01

Receive Date

2019-11-09

Publish Date

2018-12-01

Page Start

16

Page End

21

Print ISSN

1110-015X

Online ISSN

2536-9156

Link

https://adjalexu.journals.ekb.eg/article_57785.html

Detail API

https://adjalexu.journals.ekb.eg/service?article_code=57785

Order

3

Type

Original Article

Type Code

1,057

Publication Type

Journal

Publication Title

Alexandria Dental Journal

Publication Link

https://adjalexu.journals.ekb.eg/

MainTitle

INFLUENCE OF OCCLUSAL LOADING LOCATION ON THE STRAIN DEVELOPED AROUND IMPLANTS WITH TWO DIFFERENT CREST MODULE DESIGNS (IN VITRO STUDY)

Details

Type

Article

Created At

22 Jan 2023