Improving the cooling performance of a data center: impact of unit arrangement and CFD setups

Article

Last updated: 24 Dec 2024

Subjects

-

Tags

-

Abstract

Data center can be considered as the heart of any large institution; it uses for a lot of purposes such as data transfer, data storage, data analysis, etc. The performed operations release huge amount of heat, which should be cooled down. Therefore, a huge amount of energy is required for this cooling process. This work aims to improve the cooling efficiency and consequently, decrease the energy consumption, which is required for a specific data center. The improvements have been achieved by introducing two modifications: modifying the locations of heat sources (hereinafter will refer as racks units) and cooling machines (hereinafter will refer to CRACS units), and the airflow distribution path; where the suggested arrangement is different than the standard one, and changing the location of the server fan compared to the standard one. As a first step, the quality of the numerical simulation of the suggested modifications should be evaluated. This assessment was done by testing the impact of the mesh size on the air velocity and temperature as the main parameters in the current analysis. CFD Numerical investigation is done using ANSYS 16. The geometry is created using AUTOCAD 18, then it is exported to ANSYS. The meshing is created using ANSYS workbench with taken into account several mesh refinement. It was found that the suggested modifications increase the cooling performance and reduces energy consumption

DOI

10.21608/erj.2020.140126

Keywords

Data centers, Energy saving, Cooling performance

Authors

First Name

S.

Last Name

Nassar

MiddleName

-

Affiliation

Department of Mechanical Power Engineering, Faculty of Engineering at El-Mattaria, Helwan University, Masaken El-Helmia P.O., Cairo 11718, Egypt.

Email

-

City

-

Orcid

-

First Name

A.

Last Name

Abdelsamie

MiddleName

-

Affiliation

Department of Mechanical Power Engineering, Faculty of Engineering at El-Mattaria, Helwan University, Masaken El-Helmia P.O., Cairo 11718, Egypt.

Email

-

City

-

Orcid

-

First Name

A.

Last Name

Mohamed

MiddleName

-

Affiliation

Department of Mechanical Power Engineering, Faculty of Engineering at El-Mattaria, Helwan University, Masaken El-Helmia P.O., Cairo 11718, Egypt.

Email

-

City

-

Orcid

-

First Name

M.

Last Name

Sedrak

MiddleName

-

Affiliation

Department of Mechanical Power Engineering, Faculty of Engineering at El-Mattaria, Helwan University, Masaken El-Helmia P.O., Cairo 11718, Egypt.

Email

-

City

-

Orcid

-

Volume

168

Article Issue

0

Related Issue

20729

Issue Date

2020-12-01

Receive Date

2021-01-16

Publish Date

2020-12-01

Page Start

117

Page End

145

Print ISSN

1110-5615

Link

https://erj.journals.ekb.eg/article_140126.html

Detail API

https://erj.journals.ekb.eg/service?article_code=140126

Order

2

Type

Original Article

Type Code

998

Publication Type

Journal

Publication Title

Engineering Research Journal

Publication Link

https://erj.journals.ekb.eg/

MainTitle

Improving the cooling performance of a data center: impact of unit arrangement and CFD setups

Details

Type

Article

Created At

22 Jan 2023