208206

Comparison in Vitro Between Three-Dimensionally Printed, Milled Cad-Cam and Manually Fabricated Interim Crown Materials

Article

Last updated: 04 Jan 2025

Subjects

-

Tags

Prosthodontics

Abstract

Aim: The marginal and internal fit, fracture strength, and mode of failure of 3rd
printed CAD/CAM provisional crowns were compared to those of direct provisional
crowns. Subjects and Methods; Following tooth preparation guidelines upper right
first premolar Farasco tooth. 3rd printed Polyphenylene sulfone (PPSU), milled CADCAM Polyetheretherketone (PEEK) and ProtempTM4 manually fabricated were the
materials tested (control group). The crowns were divided into three groups (n=20):
Groups 1, 2, and 3: Each crown was examined for marginal and internal fit, fracture strength, and failure mode. In a universal test machine, the maximum force at
fracture (Fmax) was measured, and the mode of failure was reported at 0.5 mm/min.
ANOVA, chi-squared test, and Tukey's tests (p 0.05). Results: the average marginal
gap of PEEK(Polyetheretherketone) CAD-CAM was less than the 3rd printed PPSU
(Polyphenylene sulfone) and direct fabrication Protemp™4, PPSU 80.64±8.34 µm,
PEEK 60.64±9.54 µm, and Protemp4 120.64±32.34 µm. This indicated a statistically significant difference in the marginal gap distances between all groups (p < 0.001).
The average internal gap value for each group was: PPSU 155.32±20.56 µm, PEEK
123.45±16.11 µm, and Protemp™4 260.34±34.45 µm. There was a statistically significant difference in fracture strength between all classes. (p < 0.001). Each group's
average fracture strength was: PPSU 657.43±23.43 N, PEEK 870.45±18.87 N, and
Protemp™4 427.34±25.43 N. Conclusion. CAD/CAM PEEK temporary crowns and
the 3rd printed PPSU material exhibited significantly higher fracture strength and less
marginal and internal gap measurements than conventionally fabricated Protemp™
4 resins after the aging regimen.

DOI

10.21608/aadj.2021.208206

Keywords

Temporary dental restoration, Dental marginal adaptation, CADCAM, 3rd printed temporary crown, dental prosthesis

Authors

First Name

Raafat

Last Name

Tammam

MiddleName

A.

Affiliation

Department of Fixed Prosthodontics, Faculty of Dentistry Assiut University, Egypt.

Email

-

City

-

Orcid

-

Volume

4

Article Issue

2

Related Issue

29092

Issue Date

2021-10-01

Receive Date

2021-06-08

Publish Date

2021-10-01

Page Start

141

Page End

150

Print ISSN

2682-2822

Link

https://aadj.journals.ekb.eg/article_208206.html

Detail API

https://aadj.journals.ekb.eg/service?article_code=208206

Order

5

Type

Original Article

Type Code

974

Publication Type

Journal

Publication Title

Al-Azhar Assiut Dental Journal

Publication Link

https://aadj.journals.ekb.eg/

MainTitle

Comparison in Vitro Between Three-Dimensionally Printed, Milled Cad-Cam and Manually Fabricated Interim Crown Materials

Details

Type

Article

Created At

22 Jan 2023