Abstract

Aim: It was to compare Locator versus ball and socket attachment systems for single implant retained mandibular overdenture in relation to retention and oral health related quality of life. Subjects and Methods: Twenty completely edentulous patients were randomly selected from the Outpatient Clinic.  Patients were divided into two groups, group (I) received single implant retained overdenture with ball and socket attachment while group (II) received single implant retained overdenture with locator attachment. Retention was measured three months interval after overdenture insertion for one year using force gauge device. Oral healthrelated quality of life was evaluated using OHIP-EDENT questionnaire after one year of overdenture insertion. Results: Group (II) recorded higher retention values than group (I) and the difference was statistically  significant. Group I recorded higher Oral healthrelated quality of life mean values than group II and the difference was statistically non- significant.
 Conclusion: Locator attachment significantly increases retention of implant retained overdenture than ball and socket attachment. There is no significant difference in Patient oral health and quality of life between locator and ball attachments.

DOI

10.21608/aadj.2019.76476

Keywords

Implant, overdenture, retention, Patient oral health and quality of life, attachments, ball and socket, locators

Authors

First Name

Mostafa

Last Name

Fayad

MiddleName

I

Affiliation

Department of Substitutive Dental Science, College of Dentistry, Taibah University, Sauid Arbia.

Email

dr.mifayad@azhar.edu.eg

City

Cairo

Orcid

0000-0002-5516-0795

First Name

M

Last Name

Osman

MiddleName

A

Affiliation

Department of Removable Prosthodontics, Faculty of Dental Medicine, Al-Azhar University, (Cairo, boys), Egypt.

Email

-

City

-

Orcid

-

First Name

D

Last Name

Haddad

MiddleName

F

Affiliation

Department of Removable Prosthodontics, Faculty of Dental Medicine, Al-Azhar University, (Cairo, boys), Egypt.

Email

-

City

-

Orcid

-

First Name

M

Last Name

Quassemc

MiddleName

A

Affiliation

Department of Removable Prosthodontics, Faculty of Dental Medicine, Al-Azhar University, (Cairo, boys), Egypt.

Email

-

City

-

Orcid

-

Volume

2

Article Issue

2

Related Issue

11464

Issue Date

2019-10-01

Receive Date

2019-08-08

Publish Date

2019-10-01

Page Start

109

Page End

115

Print ISSN

2682-2822

Link

https://aadj.journals.ekb.eg/article_76476.html

Detail API

https://aadj.journals.ekb.eg/service?article_code=76476

Order

3

Type

Original Article

Type Code

974

Publication Type

Journal

Publication Title

Al-Azhar Assiut Dental Journal

Publication Link

https://aadj.journals.ekb.eg/

MainTitle

-

Details

Type

Article

Created At

22 Jan 2023