Beta
139725

ASSESSMENT OF CERVICAL LENGTH, SHAPE AND CONSISTENCY BETWEEN 18-24 WEEKS GESTATIONAL AGE BY TRANSVAGINAL ULTRASOUND FOR PREDICTION OF PRETERM LABOR

Article

Last updated: 22 Jan 2023

Subjects

-

Tags

Surgery

Abstract

Background: Preterm labor is the presence of uterine contractions of sufficient frequency and intensity to affect progressive effacement and dilation of the cervix prior to term gestation. Shortening and funneling of the cervix was first described to be associated with the diagnosis of cervical incompetence, Transvaginal sonographic measurement of cervical length could be used to predict a risk for preterm delivery for a significant proportion of preterm births. Cervical length is measured by transvaginal ultrasound from internal os to external os while the urinary bladder is empty.
Objective: To determine the value of measurement of cervical parameters by transvaginal ultrasound between 18 and 24 weeks' gestation in the prediction of spontaneous preterm delivery.
Patients and Methods: The study was carried out at Bab EL-Sha'aria University Hospital between 1/10/2018 and 31/12/2019 on 200 primigravida women with single pregnancy and intact membranes. Women with scarred uterus, women with chronic medical diseases or obstetric problems, women who underwent cerclage and fetal anomalies were excluded from the study. For all participants, transvaginal ultrasound was done between 18 and 24 weeks' gestation for measurement of cervical length, shape and consistency.
Results: Infant means weight at delivery was 1589 g with SD 215 in preterm delivery, while Infant mean weight at delivery was 3024 g with SD 200 which was significant. 33.3% of preterm birth delivered vaginally, while 66.7% delivered by C.S. 62.6% of full term delivery delivered vaginally, while 37.4% delivered by C.S. No statistically significant difference was found regarding mode of delivery. Cervical length was significant in prediction of preterm labor with sensitivity 88.9%, specificity 91.2%, PPV 50.0% and NPV 98.8 %. Cervical consistency index was significant in prediction of preterm labor with sensitivity 88.9%, Specificity 93.4%, PPV 57.1% and NPV 98.8 %. Funneling was present in 33.3% of preterm delivery, and 4.4% of full term delivery which was significant. Measurement of cervical length, shape and consistency was a reliable method for prediction of preterm labor.
Conclusion: Measurement of cervical length, shape and consistency by transvaginal ultrasound between 18 and 24 weeks' gestation was a reliable method for prediction of preterm labor.

DOI

10.21608/amj.2021.139725

Keywords

Cervical length, cervical consistency index, preterm birth

Authors

First Name

Mohamad

Last Name

Moharam Badr

MiddleName

-

Affiliation

Department of Obstetrics and Gynecology, Faculty of Medicine, Al-Azhar University, Cairo, Egypt

Email

mm3241906@gmail.com

City

-

Orcid

-

First Name

Mohamad

Last Name

Hesham Hasan Anwar

MiddleName

-

Affiliation

Department of Obstetrics and Gynecology, Faculty of Medicine, Al-Azhar University, Cairo, Egypt

Email

-

City

-

Orcid

-

First Name

Bassem

Last Name

Ragab Abd El-Aziz

MiddleName

-

Affiliation

Department of Obstetrics and Gynecology, Faculty of Medicine, Al-Azhar University, Cairo, Egypt

Email

-

City

-

Orcid

-

Volume

50

Article Issue

1

Related Issue

20574

Issue Date

2021-01-01

Receive Date

2021-01-15

Publish Date

2021-01-01

Page Start

325

Page End

334

Print ISSN

1110-0400

Link

https://amj.journals.ekb.eg/article_139725.html

Detail API

https://amj.journals.ekb.eg/service?article_code=139725

Order

29

Type

Original Article

Type Code

941

Publication Type

Journal

Publication Title

Al-Azhar Medical Journal

Publication Link

https://amj.journals.ekb.eg/

MainTitle

-

Details

Type

Article

Created At

22 Jan 2023