264925

FATIGUE PERFORMANCE & FRACTURE MODE ANALYSIS OF TWO AVAILABLE HIGH STRENGTH GLASS CERAMICS

Article

Last updated: 04 Jan 2025

Subjects

-

Tags

Prosthodontics

Abstract

ABSTRACT
Objective: As the high strength glass ceramics had attained a profound contribution in prosthodontics, it was aimed to evaluate the fatigue performance of two machinable high strength glass ceramics with further fracture mode analysis. Materials and methods: Twenty crowns were fabricated using Cerec in-Lab CAD\CAM system, ten crowns were fabricated from IPS. E.max CAD: group (EM-LDS) as control group and ten crowns were fabricated from VITA SUPRINITY: group (VS-ZLS). The completed crowns were cemented on epoxy resin dies. The cemented crowns were subjected to thermomechanical cycling for 75000 cycles, then loaded until fracture by using universal testing machine. Failure mode were assesses guided by Brukes' classification for all specimens. The collected data was statistically analyzed using Student t-test and Paired t-test while the significance level was set at P ≤ 0.05, in addition to descriptive statistics of the fracture mode analysis.
Results: There was no statistically significant difference in fatigue performance between the two tested groups with the major fracture occurrence in type III central fracture. Conclusion: both tested high strength glass ceramics are considered as acceptable modalities for restoration of single tooth restoration as both materials have comparable strength and exceeded the reported range of human masticatory forces.

DOI

10.21608/ajdsm.2022.159734.1363

Keywords

Glass ceramics, LDS, ZLS, Fatigue testing, Fracture resistance

Authors

First Name

Mohammed

Last Name

Rabea

MiddleName

-

Affiliation

Crown and Bridge Department, Faculty of Dental Medicine (Cairo-Boys), Al-Azhar University

Email

mo2dent@yahoo.com

City

Cairo

Orcid

-

First Name

Ahmad

Last Name

El-Kouedi

MiddleName

Yousri

Affiliation

Crown and Bridge, Faculty of Dental Medicine, Boys, Cairo

Email

kouedi@gmail.com

City

Cairo

Orcid

0000-0001-8726-5543

First Name

Mo'men

Last Name

Ahmad

MiddleName

-

Affiliation

Crown and Bridge Department, Faculty of Dental Medicine (Cairo-Boys), Al-Azhar University

Email

dr.moamen78@gmail.com

City

Cairo

Orcid

-

Volume

25

Article Issue

4

Related Issue

37151

Issue Date

2022-10-01

Receive Date

2022-08-31

Publish Date

2022-10-01

Page Start

417

Page End

423

Print ISSN

1110-6751

Online ISSN

2682-3314

Link

https://ajdsm.journals.ekb.eg/article_264925.html

Detail API

https://ajdsm.journals.ekb.eg/service?article_code=264925

Order

6

Type

Original Article

Type Code

848

Publication Type

Journal

Publication Title

Al-Azhar Journal of Dental Science

Publication Link

https://ajdsm.journals.ekb.eg/

MainTitle

FATIGUE PERFORMANCE & FRACTURE MODE ANALYSIS OF TWO AVAILABLE HIGH STRENGTH GLASS CERAMICS

Details

Type

Article

Created At