Beta
163583

Comparative study for the effect of two different types of attachment on supporting structures in implant retained mandibular complete overdenture

Article

Last updated: 22 Jan 2023

Subjects

-

Tags

Prosthodontics

Abstract

Objective: To compare between implant retained overdenture with two different attachments (Magnet and locator) by measuring the following: Retention. Bone changes by radiographic evaluation.
Subjects and Methods: Eight completely edentulous patients were selected from the Outpatient Clinic of the Prosthodontic Department; Faculty of Dental medicine, Al Azhar University and classified into two equal groups. Each patient in two groups received two implants placed in the mandibular canine-premolar region bilaterally. Group (1): four patients received two implants with using locator attachments. Group (2): four patients received two implants with using magnet attachments.
Results: Results revealed that, there was no statistically significant difference in bone loss between locator and magnet during the follow up period, and there were no statistically significant mean retention values in the two groups at base line and after 3 months. But 6 months; Magnet attachment showed statistically significantly lower mean retention values than Locator attachment. By time there was a statistically significant decrease in mean retention values of magnet rather than locator attachment.
Conclusion: The use of locator and magnet attachments with two implant supported mandibular overdentures leads the same amount of bone resorption around the implants. At the beginning the two attachment have the same retention quality by time magnet attachment loss some of its retention rather than locator attachment due to poor corrosive resistance of magnets within oral fluid requires encapsulation within a new hybrid material.
Keywords: Dental Implants, Overdenture, Attachment, Retention

DOI

10.21608/ajdsm.2020.35977.1084

Keywords

Dental implants, overdenture, attachment, retention

Authors

First Name

Ahmed

Last Name

Sayed

MiddleName

Sherif

Affiliation

Removable prosthodontics azhr cairo university

Email

mody808@gmail.com

City

Elsheikh Zayed

Orcid

-

Volume

24

Article Issue

1

Related Issue

23871

Issue Date

2021-01-01

Receive Date

2020-07-16

Publish Date

2021-01-01

Page Start

11

Page End

18

Print ISSN

1110-6751

Online ISSN

2682-3314

Link

https://ajdsm.journals.ekb.eg/article_163583.html

Detail API

https://ajdsm.journals.ekb.eg/service?article_code=163583

Order

2

Type

literature

Type Code

853

Publication Type

Journal

Publication Title

Al-Azhar Journal of Dental Science

Publication Link

https://ajdsm.journals.ekb.eg/

MainTitle

-

Details

Type

Article

Created At

22 Jan 2023