Subjects
-Abstract
Abstract:
Objective: This study was conducted to evaluate surface hardness of a thermoplastic nylon denture base material and comparing it with conventional heat cured acrylic resin.
Material and methods: Two different types of commercially available denture base materials were used in this study. divided two ggroups Group I: Heat cured acrylic resin denture base material. Group II: Thermoplastic nylon denture base material. each group had ten specimens .Each Specimens had dimensions of (65mm X 10mm X 2.5mm) length, width and thickness according to ADA Specifiication no 12. All species were tested using Digital Display Vicker`s microhardness test with values recorded in HV.
Results: It was found that acrylic resin group recorded statistically non-significant higher Vickers hardness mean value (33.591±1.850 HV) than Thermoplastic nylon group (31.331±2.5 HV) as indicated by unpaired t-test (P=0.0818> 0.05)
Conclusion : Thermoplastic material show to have less than the conventional acrylic resin in terms of surface hardness values.
DOI
10.21608/ajdsm.2020.34761.1079
Keywords
thermoplastic resin, Acrylic resin, complete denture, surface hardness
Authors
Affiliation
prosthesis, azhar
Email
mohamedshata.209@azhar.edu.eg
Orcid
-Link
https://ajdsm.journals.ekb.eg/article_140884.html
Detail API
https://ajdsm.journals.ekb.eg/service?article_code=140884
Publication Title
Al-Azhar Journal of Dental Science
Publication Link
https://ajdsm.journals.ekb.eg/
MainTitle
-