Frequent forced outages of power transformers can significantly affect the performance of industrial and commercial power systems and the processes they control. This paper presents the results of an extensive survey on false tripping of protection devices and systems for power transformers in Egypt. The outcomes of this work are beneficial in improving the design and maintenance of these protection systems to increase the reliability and availability of power systems. The data are obtained from the Egyptian Electricity Transmission Company (EETC). The collected data are in the form of transformer outage reports for eight years, from 2002 to 2009, where the average number of transformers is 1922 in voltage populations ranging from 33 kV to 500 kV and MVA rating from 5 MVA to 500 MVA. Results show that the fire-fighting systems are responsible for the highest number of false trips in all voltage sub-populations except the 220 kV sub-population where the dominant cause of false trips is the bus bar protection.

DOI

10.21608/iceeng.2012.30673

Keywords

Power transformers, protection systems, false tripping

Authors

First Name

M.

Last Name

Abdelfatah

MiddleName

-

Affiliation

Electrical testing and transformers section, EETC. Ministry of Electricity, Cairo, Egypt.

Email

-

City

-

Orcid

-

First Name

M.

Last Name

EL-Shimy

MiddleName

-

Affiliation

Electrical Power and Machines Department. Faculty of Engineering, Ain Shams University, Cairo, Egypt. P.O. Box (11517).+, Corresponding author: M. ELShimy.

Email

-

City

-

Orcid

-

First Name

H.

Last Name

Ismail

MiddleName

M.

Affiliation

Electrical Power and Machines Department. Faculty of Engineering, Ain Shams University, Cairo, Egypt. P.O. Box (11517).

Email

-

City

-

Orcid

-

Volume

8

Article Issue

8th International Conference on Electrical Engineering ICEENG 2012

Related Issue

5272

Issue Date

2012-05-01

Receive Date

2019-04-24

Publish Date

2012-05-01

Page Start

1

Page End

10

Print ISSN

2636-4433

Online ISSN

2636-4441

Link

https://iceeng.journals.ekb.eg/article_30673.html

Detail API

https://iceeng.journals.ekb.eg/service?article_code=30673

Order

38

Type

Original Article

Type Code

833

Publication Type

Journal

Publication Title

The International Conference on Electrical Engineering

Publication Link

https://iceeng.journals.ekb.eg/

MainTitle

Analysis of false tripping for power transformers in Egypt

Details

Type

Article

Created At

22 Jan 2023