Beta
203496

Comparison Between the Roles of Trans-abdominal 3D Ultrasound Versus Transvaginal 2D Ultrasound in Evaluation of Placental Invasion in Cases of Placenta Previa with Previous Uterine Scar

Article

Last updated: 22 Jan 2023

Subjects

-

Tags

Gynecology and Obstetrics

Abstract

Background: The correct diagnosis of placenta previa is a crucial task to prevent associated complications. Ultrasound is considered the gold standard technique. However, the appropriate technique, with 100% sensitivity is not yet determined.
The aim of the work: The current study aimed to compare the transabdominal 3D versus transvaginal 2D ultrasound in the assessment of placental invasion in women with placenta previa with previous uterine scar.
Patients and Methods: The study included sixty patients with confirmed ultrasound placenta previa. Each patient was evaluated by the full history taking, clinical examination. Finally, ultrasound was performed for all women. The placenta was examined while the bladder is partially full [about 300 ml] for adequate visualization and precise localization. A complete US scan had been performed and included 2D vaginal ultrasound, and 3D abdominal ultrasound. At delivery, intraoperative definitive diagnosis of abnormally invasive placenta was made. Data compared to the previous ultrasound diagnosis.
Results: The hematocrit value was significantly decreased after the operation compared to preoperative values [27.16 ± 2.51 vs 30.92 ± 2.78, respectively, p = 0.024]. The sensitivity of 3D transabdominal ultrasound was 53.3%, 65.0%, 88.3% and 73.3% for the detection of retroplacental clear zone, myometrial thinning, uterovesical vascularity and bladder wall interruption, successively. Otherwise, the 2D transvaginal ultrasound sensitivity was 75%, 71.6%, 83.3% and 7.7% for the same conditions. The 3D transabdominal US was 72.5% sensitive, 90% specific, 84.1% PPV, 60.9% NPV and 76.7% accuracy. The 2D transvaginal US revealed 87.4% sensitivity, 73.7% specificity, 93.3% PPV, 41.6% NPV and 89.3% accuracy.
Conclusion: 2D vaginal ultrasound is more sensitive compared to the 3-D abdominal sonography in detecting placenta previa. However, the 3D transabdominal US higher sensitivity in detecting some radiological signs of this lesions like uterovesical vascularity.  

DOI

10.21608/ijma.2021.85082.1340

Keywords

Ultrasound, Transabdominal, Transvaginal, Three Dimensional, Cesarean section scar

Authors

First Name

Abdelhalim Hammouda

Last Name

Hammouda

MiddleName

Abdelhalim

Affiliation

Department of Obstetrics and Gynecology, Sherbin General Hospital, Ministry of Health, Egypt

Email

7aleem90@google.com

City

-

Orcid

-

First Name

Abd Elraouf Mohammad

Last Name

Oun

MiddleName

-

Affiliation

Department of Obstetrics and Gynecology, Damietta Faculty of Medicine, Al-Azhar University, Egypt

Email

raoufoun2016@yahoo.com

City

Kafr Elsheikh

Orcid

-

First Name

Mahmoud

Last Name

Mahmoud

MiddleName

salah

Affiliation

Department of Obstetrics and Gynecology, Damietta Faculty of Medicine, Al-Azhar University, Egypt

Email

dr.m.s.rady@gmail.com

City

-

Orcid

0000-0002-5858-9263

First Name

Hamada

Last Name

Aboelmaaty

MiddleName

-

Affiliation

Department of Obstetrics and Gynecology, Damietta Faculty of Medicine, Al-Azhar University, Egypt

Email

hamadamatti44@gmail.com

City

-

Orcid

-

Volume

4

Article Issue

1

Related Issue

30177

Issue Date

2022-01-01

Receive Date

2021-07-09

Publish Date

2022-01-01

Page Start

1,947

Page End

1,954

Print ISSN

2636-4174

Online ISSN

2682-3780

Link

https://ijma.journals.ekb.eg/article_203496.html

Detail API

https://ijma.journals.ekb.eg/service?article_code=203496

Order

1

Type

Original Article

Type Code

816

Publication Type

Journal

Publication Title

International Journal of Medical Arts

Publication Link

https://ijma.journals.ekb.eg/

MainTitle

-

Details

Type

Article

Created At

22 Jan 2023