Background: Measurement of intraocular pressure is one of the most important examination procedures in ophthalmic clinics, IOP is an important parameter in the diagnosis of glaucoma. There are numerous types of tonometers available, it is important to evaluate the differences in readings between different tonometers. Goldmann Applanation Tonometers and non-contact Air-Puff Tonometers are largely available in ophthalmic clinics.
Aim: The purpose of this study is to evaluate the difference between IOP measurements taken by a GAT and those taken by an Air Puff Tonometer and to observe the reliability of Air Puff to be a screening tool.
Material and Methods: This study was performed on 200 eyes from 100 study participants (including: Relatives of patients, medical students, nurses and patients complaining from errors of refraction). attending an ophthalmic outpatient clinic. visual acuity, Refraction, fundus examination, corneal thickness were assessed for each participant; Also, each patient's IOP was measured using both GAT and Air-Puff tonometry, the difference in readings between the two methods were calculated.
Result: The mean IOP measured by GAT was 14.48±2.29 mmHg, while that measured by Air Puff tonometer was 16.34±2.3 mmHg. The mean difference between the two methods of measurement was 1.855 mmHg. The readings obtained by Air Puff tonometer were higher than those obtained by GAT and highly statistically significant.
Conclusion: The non-contact, air puff, tonometer produces IOP measurements which are similar & consistent to that of gold standard GAT. Our study indicated that there is a good consistency between the non-contact Air-Puff tonometer and GAT.

DOI

10.21608/bmfj.2021.17077.1062

Keywords

Keywords: IOP, non contact tonometry, Goldmann Applanation Tonometer

Authors

First Name

Rowaida

Last Name

Basuony

MiddleName

Elsayed

Affiliation

Ophthalmology, Benha Faculty of Medicine, Benha, Qalubia

Email

rodyali2020@gmail.com

City

Benha

Orcid

-

First Name

Waheed

Last Name

Orouk

MiddleName

Mahmoud

Affiliation

Ophthalmology, Faculty of Medicine, Benha University

Email

waheedorouk@yahoo.com

City

-

Orcid

-

First Name

Tarek

Last Name

Soliman

MiddleName

Tawfik

Affiliation

Ophthalmology, Faculty of Medicine, Benha University

Email

ttawfik68@yahoo.com

City

-

Orcid

-

First Name

Tarek

Last Name

Attia

MiddleName

Nehad

Affiliation

Ophthalmology, Faculty of Medicine, Benha University

Email

tarekn73@hotmail.com

City

-

Orcid

-

Volume

39

Article Issue

Special issue (Ophthalmology)

Related Issue

29564

Issue Date

2022-01-01

Receive Date

2019-09-21

Publish Date

2022-01-01

Page Start

49

Page End

58

Print ISSN

1110-208X

Online ISSN

2357-0016

Link

https://bmfj.journals.ekb.eg/article_191408.html

Detail API

https://bmfj.journals.ekb.eg/service?article_code=191408

Order

5

Type

Original Article

Type Code

787

Publication Type

Journal

Publication Title

Benha Medical Journal

Publication Link

https://bmfj.journals.ekb.eg/

MainTitle

Comparison Of Intraocular Pressure (IOP) Measured By Non-Contact (Air–Puff) Tonometer Compared With Goldmann Applanation Tonometer

Details

Type

Article

Created At

22 Jan 2023