109131

Comparison of Intraocular Pressure Measurement by Goldmann Applanation Tonometer and Air Puff Tonometer in Silicone Filled Eyes.

Article

Last updated: 04 Jan 2025

Subjects

-

Tags

-

Abstract

Background: To compare intraocular pressure (IOP) measurements in silicone filled eyes by Goldmann applanation tonometer (GAT) and air puff tonometer (APT). Aim: The purpose of this study was to evaluate the role of APT by comparing the measurements of IOP made using it with those made using a GAT. Methods: In this prospective comparative study, 40 eyes with silicone oil tamponade were included. IOP was measured by GAT and air puff tonometer at least 1 month from vitrectomy. Results: in eyes with silicone oil, IOP was 21.35±12.34 mmHg and 19.46±5.29 mmHg using GAT and APT, respectively (p>0.05)  and this difference was not statistically significant (p=0.074).  In addition, no significant correlation was detected between IOP measurements using both techniques and gender, and lens status. Conclusion: It seems that GAT provided higher IOP measurements by 3.34 mmHg (95% CI = 2.15 to 4.53 mmHg) on average compared with APT but the difference between the two IOP measurements was statistically non-significant (p >0.05), in silicone filled eyes. The further assessment of available methods for IOP measurement could possibly establish the most accurate technique for IOP estimation in silicone filled eyes.

DOI

10.21608/bmfj.2020.109131

Keywords

Intraocular Pressure, Goldmann applanation tonometry, Air puff tonometry, Silicone Oil

Authors

First Name

Ashraf

Last Name

El Shayeb

MiddleName

-

Affiliation

Department of Ophthalmology, Benha faculty of medicine, Benha University, Egypt.

Email

dr_mohamedbaz@hotmail.com

City

-

Orcid

-

First Name

Mohamed

Last Name

Elmohamady

MiddleName

-

Affiliation

Department of Ophthalmology, Benha faculty of medicine, Benha University, Egypt.

Email

mohamednagy81@gmail.com

City

-

Orcid

-

First Name

Noha

Last Name

Kilany

MiddleName

-

Affiliation

Department of Ophthalmology, Benha faculty of medicine, Benha University, Egypt

Email

noha_kilany@yahoo.com

City

-

Orcid

-

Volume

37

Article Issue

3

Related Issue

17391

Issue Date

2020-09-01

Receive Date

2020-08-23

Publish Date

2020-09-01

Page Start

667

Page End

677

Print ISSN

1110-208X

Online ISSN

2357-0016

Link

https://bmfj.journals.ekb.eg/article_109131.html

Detail API

https://bmfj.journals.ekb.eg/service?article_code=109131

Order

17

Type

Original Article

Type Code

787

Publication Type

Journal

Publication Title

Benha Medical Journal

Publication Link

https://bmfj.journals.ekb.eg/

MainTitle

Comparison of Intraocular Pressure Measurement by Goldmann Applanation Tonometer and Air Puff Tonometer in Silicone Filled Eyes.

Details

Type

Article

Created At

22 Jan 2023