77362

Evaluation of the accuracy of low dose CT in the detection of urolithiasis in comparison to standard dose CT

Article

Last updated: 03 Jan 2025

Subjects

-

Tags

-

Abstract

Objective: This study aims to evaluate the sensitivity, specificity, and accuracy of low dose CT in the detection of urolithiasis in comparison with standard-dose CT as a reference test.
Materials and Methods: This prospective randomized study was conducted on 30 patients with suspected renal colic undergone standard and low dose CT from September 2018 to September 2019 at AL-Zahraa University Hospital. The patients were scanned by the Toshiba CT system, 160 slices using automated tube current modulation; the computed tomography was performed without oral or intravenous contrast.
Results: This study enrolled 30 patients who had renal colic symptoms and signs and had a urinary stone that detected in standard-dose CT, the mean of age was (43.83±11.45). The male percentage was (56.7%) while the female percentage was (43.3%). This study was revealed that 55 stones were detected by SDCT and 53 stones were detected by LDCT, so there was a statistically significant agreement between the two modalities in the detection of urolithiasis with Kappa value of (0.868) and p-value(<0.001**). The mean current tube was (416.0±79.1) and (135.2±25.7) in SDCT and LDCT respectively. The radiation dose was (120 and 80) in SDCT &LDCT respectively. Sensitivity was (96.4%) and specificity was (100%) in LDCT.
Conclusion: This study revealed that LDCT was an effective technique in the detection of urolithiasis with high sensitivity and specificity despite a significant reduction in radiation dose exposure to SDCT.

DOI

10.21608/aimj.2020.22462.1082

Keywords

urolithiasis, low dose computed tomography, standard dose computed tomography

Authors

First Name

amany

Last Name

soliman

MiddleName

ahmed

Affiliation

al-zahraa university hospital

Email

damanyahmed@gmail.com

City

Cairo

Orcid

-

First Name

lobna

Last Name

sakr

MiddleName

khaled

Affiliation

al-zahraa university hospital

Email

lobnakhaled910@hotmail.com

City

Cairo

Orcid

-

Volume

1

Article Issue

2

Related Issue

11074

Issue Date

2020-02-01

Receive Date

2020-01-20

Publish Date

2020-02-01

Page Start

209

Page End

214

Print ISSN

2682-3381

Online ISSN

2682-339X

Link

https://aimj.journals.ekb.eg/article_77362.html

Detail API

https://aimj.journals.ekb.eg/service?article_code=77362

Order

10

Type

Original Article

Type Code

710

Publication Type

Journal

Publication Title

Al-Azhar International Medical Journal

Publication Link

https://aimj.journals.ekb.eg/

MainTitle

Evaluation of the accuracy of low dose CT in the detection of urolithiasis in comparison to standard dose CT

Details

Type

Article

Created At

22 Jan 2023