Beta
265713

NUMERICAL SIMULATION FOR SEAWATER AIR PRECOOLER

Article

Last updated: 03 Jan 2025

Subjects

-

Tags

Mechanical engineering

Abstract

The low-temperature seawater is an important renewable source used for direct and indirect seawater air conditioning. In the northern Arabian Gulf, the water depth is insufficient for direct seawater air conditioning. So, for such circumstances, seawater can be utilized as an auxiliary for precooling the returned air from the conditioned space. In this study, atwo-dimensional numerical simulation model of crossflow for a 20-tube bank in a staggered arrangement with a diameter of 25 mm was investigated, with the pitch ratio SL/D and ST/D as 1.5 and 1.25 respectively. The air inlet velocity ranged from 2 to 5 m/s, the air inlet temperature is 28oC, and the seawater temperature of 21oC was considered. This paper summarizedthe numerical study to predict the performance of a heat exchanger an as air precoolerby utilizing the seawater as a cold stream. The effect of tube bank arrangement is also investigated. ANSYS 20 was applied for the numerical simulation, and the best results obtained of the temperature after the air precooling coil is 22.75oC that resulting in the efficiency of the air conditioning systemmaximum improvement by 37.5 %.  ماء البحر بدرجة حراره منخفضه مصدر مهم للطاقه النظيفه يمكن استخدامه لتكييف الهواء المباشر وغير المباشر.في شمال الخليج العربي درجة حرارة ماء البحر غير كافيه لهذا الغرض كون الأعماق ضحلهلذا ممكن الاستفاده منها في التبريد الابتدائي. في هذه الدراسه تم دراسة مقاطع طوليه لنماذج ثنائية الابعاد لحزمة انابيب مكونه أكثر من 20 أنبوب بأقطار 25 ملم مرتبه على شكل خطي وثلاثي، نسبة الخطوه الطوليه والعرضيه الى القطر هي 1.5 و1.25، سرعة دخول الهواء بين 2 الى 5 م/ثا، درجة حرارة الهواء الداخل للمبادل الحراري هي 28 مo ودرجة حرارة ماء البحر هي 21 مo استخدمت معطيات لتشغيل البرنامج، تم اختيار النموذج 20 أنبوب ثنائي الترتيب لأفضلية النتائج. استخدم برنامج ANSYS20  مع ديناميك السوائل الحسابيه CFD  لحل معادلات الكتله والزخم والطاقه والسرعه ,  أظهرت النتائج  الحصول على درجات حراره بعد المبادل  22.75 م وهذا مما يزيد من كفاءة  منظومة  التبريد بنسبة 37.5%.

DOI

10.21608/auej.2022.265713

Keywords

heat exchanger, airflow, pre-cooling process, seawater temperature

Authors

First Name

Husain

Last Name

Etaiwe

MiddleName

Ali

Affiliation

Mechanical Engineering Department, Faculty of Engineering at Shoubra, Benha University, Cairo, Egypt

Email

husain965@yahoo.com

City

-

Orcid

-

First Name

R.

Last Name

Sakr

MiddleName

Y.

Affiliation

Mechanical Engineering Department, Faculty of Engineering at Shoubra, Benha University, Cairo, Egypt

Email

-

City

-

Orcid

-

First Name

M.

Last Name

Salem

MiddleName

R

Affiliation

Mechanical Engineering Department, Faculty of Engineering at Shoubra, Benha University, Cairo, Egypt

Email

-

City

-

Orcid

-

First Name

H.

Last Name

Abdelrahman

MiddleName

E

Affiliation

Mechanical Engineering Department, Faculty of Engineering at Shoubra, Benha University, Cairo, Egypt

Email

-

City

-

Orcid

-

Volume

17

Article Issue

65

Related Issue

37220

Issue Date

2022-10-01

Receive Date

2022-06-26

Publish Date

2022-10-01

Page Start

1,241

Page End

1,260

Print ISSN

1687-8418

Link

https://jaes.journals.ekb.eg/article_265713.html

Detail API

https://jaes.journals.ekb.eg/service?article_code=265713

Order

8

Type

Original Article

Type Code

706

Publication Type

Journal

Publication Title

Journal of Al-Azhar University Engineering Sector

Publication Link

https://jaes.journals.ekb.eg/

MainTitle

NUMERICAL SIMULATION FOR SEAWATER AIR PRECOOLER

Details

Type

Article

Created At

22 Jan 2023