Beta
120371

OPTIMAL LOCATION AND SIZING OF SVC CONSIDERING SYSTEM LOSSES, VOLTAGE DIVISION AND SYSTEM OVERLOAD

Article

Last updated: 03 Jan 2025

Subjects

-

Tags

-

Abstract

Flexible Alternating Current Transmission Systems (FACTS) devices have been suggested as an efficient solution for regulating bus voltage and controlling in power flow in electrical power networks, which leads to improve stability and reduce the loss of electrical power. Suitable location and the appropriate size of these devices can lead to control line flow and maintain the voltage at each bus at the desired level and so recover system security. This paper shows comparison study between two techniques from artificial intelligent techniques to determine location and optimal size of FACTS devices based on power losses, voltage division and system over load. Also, in this paper a comparison between multi- and single objective function to find the optimal location and optimal size of SVC has been carried out. The proposed algorithms are simulated annealing and particle swarm optimization and are tested on modified IEEE 30-bus power system for optimal allocation of Static VAR Compensator (SVC) as a kind of FACTS devices and results are presented.
 
تم اقتراح أجهزة تعويض القدرة غير الفعالة کحل فعال لتنظيم جهد الناقل والتحکم في تدفق الطاقة في شبکات القدرة الکهربائية ، مما يؤدي ذلک إلى تحسين الاستقرار وتقليل فقدان الطاقة الکهربائية. يمکن أن يؤدي الموقع المناسب والسعة المناسبه لهذه النبائط إلى التحکم في تدفق سريان القدرة والحفاظ على الجهد عند کل ناقل في المستوى المطلوب وبالتالي استعادة أمان المنظومة الکهربية. تم في هذا البحث عرض دراسة مقارنة بين خوارزمية محاکاة التلدين وتحسين سرب الجسيمات لتحديد موقع وسعة أجهزة تعويض القدرة غيرالفعالة على أساس فقدان الطاقة وتقليل الفقد في الجهد وخفض حمولة المنظومة الکهربية . أيضا ، يقارن هذا البحث بين مشکلة التحسين متعددة الأهداف ومشکلة التحسين ذات الهدف الواحد للعثورعلى الموقع والسعة المثلي لـمعوض القدرة غير الفعالة. وقد تم اختبار الخوارزمية المقترحة على منظومة المعدل للبحث عن الموقع والسعة المثلي لمعوض القدرة غير الفعالة کنوع من أجهزة تعويض القدرة غير الفعالة وقد تم عرض نتائج هذا الإختبار.

DOI

10.21608/auej.2020.120371

Keywords

Flexible Alternating Currents Transmission System (FACTS), Static VAR Compensator (SVC), Multi-objective Optimization Problem (MOP), Simulated Annealing (SA), Particle Swarm Optimization (PSO). أجهزة تعويض القدرة غير الفعالة, معوض القدرة غير الفعالة, مشکلة تحسين متعددة الأهداف, محاکاة التلدين, تحسين سرب الجسيمات

Authors

First Name

H

Last Name

M. Kanaan

MiddleName

A

Affiliation

Electrical Engineering Department, Faculty of Engineering, Al-Azhar University, Nasr City, Cairo, Egypt.

Email

hamdy.mohamed@azhar.edu.eg

City

-

Orcid

-

First Name

M

Last Name

EL-Gazaar

MiddleName

M

Affiliation

Electrical Engineering Department, Faculty of Engineering, Al-Azhar University, Nasr City, Cairo, Egypt.

Email

-

City

-

Orcid

-

First Name

M

Last Name

A. Mehanna

MiddleName

A

Affiliation

Electrical Engineering Department, Faculty of Engineering, Al-Azhar University, Nasr City, Cairo, Egypt.

Email

-

City

-

Orcid

-

Volume

15

Article Issue

57

Related Issue

18027

Issue Date

2020-10-01

Receive Date

2020-10-25

Publish Date

2020-10-01

Page Start

1,040

Page End

1,051

Print ISSN

1687-8418

Link

https://jaes.journals.ekb.eg/article_120371.html

Detail API

https://jaes.journals.ekb.eg/service?article_code=120371

Order

12

Type

Original Article

Type Code

706

Publication Type

Journal

Publication Title

Journal of Al-Azhar University Engineering Sector

Publication Link

https://jaes.journals.ekb.eg/

MainTitle

OPTIMAL LOCATION AND SIZING OF SVC CONSIDERING SYSTEM LOSSES, VOLTAGE DIVISION AND SYSTEM OVERLOAD

Details

Type

Article

Created At

22 Jan 2023