Abstract

The applications of post tensioned concrete have increased and have now been used in
different regions of the world. There are only few studies which have studied the behavior of
retrofitted prestressed concrete experimentally, with the major part of the studies focusing on
retrofitted reinforced concrete. This research study is initiated by a desire to more fully
investigate the response of it. This paper presents a parametric study established on a beam
with T-sec with web width 700 mm and a height of 1800mm, the thickness of the flange is
150 mm, the width of beam flange is 1500mm with span 29.6m. The beam was simply
supported and loaded uniformly. A total no. of 20 finite element 3D models was generated
taking the all possible failure modes such as FRP rupture, concrete cover separation and
concrete crushing in order to study percentage of prestressing steel (Wp) parameter. Finally, a
comparison is done between ACI 440.2R-08 code and the finite element results for the
ultimate failure load and the predicted failure mode 0.
 
تطبيقات الخرسانة سابقة الإجھاد أصبحت واسعة الانتشار في کل إنحاء العالم وخاصة في الکباري الخراسانية ذات البحور
الطويلة في حدود ٣٠ إلي ٤٠ متر لذلک کان لابد من دراسة تدعيم او تقوية ھذا النظام باستخدام الفيبر المسلح المدفون
بالقرب من السطح.في الوقت الحالي کانت غالبية الدراسات ترکز علي تدعيم الخرسانة المسلحة ويوجد حاليا دراسات
بسيطة تطرقت الي ھذا المجال عمليا فقط لذلک ترکزت ھذه الدراسة علي الناحية النظرية و التمثيل الدقيق لسلوک الکمرة
المدعمة للحصول علي حمل الکسر وتحديد نوع الانھيار.جميع ھذه الکمرات لھا ارتفاع ثابت ھو ١٨٠٠ مم وعرض جزع T-section تم عمل دراسة نظرية علي کمرة بقطاع
الکمرات ٧٠٠ مم وسمک الشفة العلوية (البلاطة) ١٥٠ مم و بعرض ثابت قدره ١٥٠٠ مم .وتم تدعيم ھذه الکمرات
بالقضبان البوليمارية المدفونة بالقرب من السطح بإعداد مختلفة وکانت الکمرة بسيطة الارتکاز محملة بحمل موزع.
تدرس تأثير النسبة المئوية لکابلات سابقة الشد في ABAQUS حيت تم عمل 20 نموذج تحليلي باستخدام برنامج ال
ACI 440.2R- القطاع.ولکي يتم تقييم النتائج النظرية تم عمل مقارنة حمل الانھيار ونوع الانھيار بين الکود الأمريکي 0.8

DOI

10.21608/auej.2019.64241

Keywords

Posttensioned beam, FRP, NSM, reinforced concrete beams, Strengtheningکمرة لاحقة الشد – الفيبر المسلح بالبوليمر-الالياف المدفونة بالقرب من السطح- کمر مسلح-التدعيم

Authors

First Name

Belal

Last Name

Elharouney

MiddleName

Hesham

Affiliation

Structural design engineer at ASGC, Misr algadida, Cairo, Egypt

Email

belalelharouney@gmail.com

City

-

Orcid

-

First Name

Ayman

Last Name

Hussein

MiddleName

-

Affiliation

Structural Engineering Department, Faculty of Eng., Ain Shams University, Cairo, Egypt

Email

-

City

-

Orcid

-

First Name

Ezz El-Deen

Last Name

Mostafa

MiddleName

-

Affiliation

Structural Engineering Department, Faculty of Eng., Ain Shams University, Cairo, Egypt

Email

-

City

-

Orcid

-

First Name

Amr

Last Name

Elnemr

MiddleName

-

Affiliation

Structural Engineering Department, German University, Cairo, Egypt

Email

-

City

-

Orcid

-

Volume

14

Article Issue

53

Related Issue

9671

Issue Date

2019-10-01

Receive Date

2019-12-08

Publish Date

2019-10-01

Page Start

1,424

Page End

1,435

Print ISSN

1687-8418

Link

https://jaes.journals.ekb.eg/article_64241.html

Detail API

https://jaes.journals.ekb.eg/service?article_code=64241

Order

19

Publication Type

Journal

Publication Title

Journal of Al-Azhar University Engineering Sector

Publication Link

https://jaes.journals.ekb.eg/

MainTitle

-

Details

Type

Article

Created At

22 Jan 2023