280179

Results of Dynamic Hip Screw with Trochanteric Stabilizing Plate in Treatment of Unstable Trochanteric Hip Fractures

Article

Last updated: 03 Jan 2025

Subjects

-

Tags

-

Abstract

Background: Trochanteric hip fractures are common among elderly patients. They are categorized as stable and unstable fractures depending on integrity of postero-medial cortex. Integrity of lateral wall is important to prevent excessive fracture collapse and poor outcome. Objective: This study aimed to assess the results of using dynamic hip screw with trochanteric stabilizing plate (TSP) in management of unstable trochanteric fractures (A2 and A3 patterns in AO classification). Patients and methods: Forty patients with unstable hip fractures were operated in Kasr Alainy Hospital using dynamic hip screw (DHS) with TSP. The study had a minimum follow up of 18 months. Results: In this study, operative time ranged from 90 to 180 minutes with mean of 105.5 ± 24.06. Six patients (15%) had 500 cc packed RBCs transfusion and only one case (2.5%) needed 1000 cc of packed RBCs. At 6 weeks HSS ranged from 20 to 80 points, the mean was 54.94 ± 16.17 points. At 3 months the HSS ranged from 43 to 89 points, the mean was 70.22 ±12.65 points. At 6 months the HSS ranged from 50 to 100 points, the mean was 82.81 ±10.37 points. At 12 months the HSS ranged from 55 to 100 points, the mean was 89.09 ±9.20 points. At 18 months the HSS ranged from 62 to 100 points, the mean was 93.84 ± 7.95 points. Conclusion: TSP is a good option in management of unstable trochanteric fractures. We recommend making more studies on TSP to reveal its efficacy.  

DOI

10.21608/ejhm.2023.280179

Keywords

Dynamic, hip, Screw, Trochanteric, Hip Fractures

Authors

First Name

Mohammed Mazher Mohammed

Last Name

Saif

MiddleName

-

Affiliation

-

Email

dr_m_seif@yahoo.com

City

-

Orcid

-

First Name

Mohamed Omar

Last Name

Soliman

MiddleName

-

Affiliation

-

Email

-

City

-

Orcid

-

First Name

Mohamed Said

Last Name

Abd El Maksoud

MiddleName

-

Affiliation

-

Email

-

City

-

Orcid

-

First Name

Mohamed Ahmed

Last Name

Abd El Moneim

MiddleName

-

Affiliation

-

Email

-

City

-

Orcid

-

First Name

Mahmoud Fahmy

Last Name

Tayel

MiddleName

-

Affiliation

-

Email

-

City

-

Orcid

-

Volume

90

Article Issue

1

Related Issue

38787

Issue Date

2023-01-01

Receive Date

2023-01-13

Publish Date

2023-01-01

Page Start

655

Page End

659

Print ISSN

1687-2002

Online ISSN

2090-7125

Link

https://ejhm.journals.ekb.eg/article_280179.html

Detail API

https://ejhm.journals.ekb.eg/service?article_code=280179

Order

91

Type

Original Article

Type Code

606

Publication Type

Journal

Publication Title

The Egyptian Journal of Hospital Medicine

Publication Link

https://ejhm.journals.ekb.eg/

MainTitle

Results of Dynamic Hip Screw with Trochanteric Stabilizing Plate in Treatment of Unstable Trochanteric Hip Fractures

Details

Type

Article