Beta
247137

Correlation between Ultrasound Measurements of Internal Jugular Venous Diameter and Central Venous Pressure Measurements as a Follow up Tool in Severe Sepsis

Article

Last updated: 24 Dec 2024

Subjects

-

Tags

-

Abstract

Background: Sepsis is one of the primary causes of death among intensive care unit (ICU) patients. Proper and controlled fluid administration is needed in septic patients to overcome generalized vasodilatation and capillary leak that worsen septic patients. Objective: Current study aimed to evaluate ultrasonographic measurements of internal jugular vein (IJV) as a predictor for volume status and to define its role in improvement of haemodynamic, urine output and mortality rate among septic patients.
Patients and Methods: Fifty-one adult septic patients were enrolled from ICU of Mansoura University Hospitals who already inserted central venous catheter (CVC) for appropriate indication took part in an observational study. Continuous monitoring of hemodynamic parameters was carried out. Ultrasound guided IJV diameter was assessed when patients were lying down, then central venous pressure (CVP) measurements were taken. Signs of hypovolemia, such as tachycardia, hypotension, and acidosis were assessed clinically.
Results: Data from 51 septic patients who were spontaneously breathing were evaluated. There was significant positive correlation between CVP and both width and height (at admission, 3h or 24 hours following the admission). Systolic blood pressure (SBP) demonstrated statistically significant positive correlation at admission (width and height) and after 24 hours of admission with width. Diastolic blood pressure (DBP) and mean arterial pressure (MAP) demonstrated statistically significant positive correlation at admission (width and height) and after 3 hours of admission with height.
Conclusions: Ultrasonographic measurement of the IJV is a good predictor of fluid response in septic patients.
 

DOI

10.21608/ejhm.2022.247137

Keywords

Central venous pressure, internal jugular vein, Septic shock

Authors

First Name

shaimaa

Last Name

salem

MiddleName

Atef

Affiliation

Anesthesia ,Surgical ICU and pain management departement , Faculty of Medicine ,Mansoura university ,Egypt

Email

shemo_167@hotmail.com

City

mansoura

Orcid

0000-0003-4019-0892

First Name

Amal Rashad

Last Name

Ryad

MiddleName

-

Affiliation

-

Email

-

City

-

Orcid

-

First Name

Enas Aly

Last Name

Abdelmotleb

MiddleName

-

Affiliation

-

Email

-

City

-

Orcid

-

First Name

Tamer Elmetwally

Last Name

Farahat

MiddleName

-

Affiliation

-

Email

-

City

-

Orcid

-

Volume

88

Article Issue

1

Related Issue

33970

Issue Date

2022-07-01

Receive Date

2022-07-01

Publish Date

2022-07-01

Page Start

3,267

Page End

3,271

Print ISSN

1687-2002

Online ISSN

2090-7125

Link

https://ejhm.journals.ekb.eg/article_247137.html

Detail API

https://ejhm.journals.ekb.eg/service?article_code=247137

Order

157

Type

Original Article

Type Code

606

Publication Type

Journal

Publication Title

The Egyptian Journal of Hospital Medicine

Publication Link

https://ejhm.journals.ekb.eg/

MainTitle

Correlation between Ultrasound Measurements of Internal Jugular Venous Diameter and Central Venous Pressure Measurements as a Follow up Tool in Severe Sepsis

Details

Type

Article

Created At

22 Jan 2023