Background: Ultrasound assessment of optic nerve sheath diameter (ONSD) has been used as a promising tool to aid in the diagnosis of elevated intracranial pressure (ICP). Optic nerve sheath is contiguous with the dura matter surrounding the brain and contains cerebrospinal fluid, which allows transmission of pressure from the cranium. Objective: To determine the diagnostic accuracy of measurement of ONSD by using ocular ultrasonography to detect elevated ICP in patients with TBI in Emergency Department. Patients and methods: This prospective cross-sectional observational study that was carried out on 99 patients presented and admitted to Mansoura University Emergency Hospital with traumatic brain injury (TBI) over a year from June 2020 to June 2021. Results: The clinical features of raised ICP had low specificity (38%), positive predictive value (PPV) (61.7%), and accuracy (69%) for diagnosis of raised ICP with high significant statistical difference (62% vs 100%) towards group 2. The ONSD were much higher (P <0.01) in group 2 (6.493 ± 0.586 mm) than group 1 (3.93 ± 0.976 mm). The cutoff value of binocular mean ONSD for diagnosing raised ICP was > 5 mm with sensitivity of 100 %, specificity of 96%, and accuracy of 99%. The optimal cutoff value to predict mortality rate was >6.8 mm with modest sensitivity and accuracy. While the optimal value to predict unfavorable Glasgow Outcome Scale (GOS) was >6.05 mm with high sensitivity and accuracy. Conclusion: ONSD measurement via bedside ocular ultrasound is a useful, non-invasive method for early diagnosis of elevated ICP in adult patients with TBI in the Emergency Department.  

DOI

10.21608/ejhm.2021.194063

Keywords

Intracranial pressure, Optic Nerve Sheath Diameter Measurement, Traumatic brain injury

Authors

First Name

Sanaa Magdi Mohamed

Last Name

Mahmoud

MiddleName

-

Affiliation

-

Email

dr.idol96@gmail.com

City

-

Orcid

-

First Name

Samir Mohamed

Last Name

Attia

MiddleName

-

Affiliation

-

Email

-

City

-

Orcid

-

First Name

Mohamed Ali

Last Name

El Adalany

MiddleName

-

Affiliation

-

Email

-

City

-

Orcid

-

First Name

Mohamed El Saeed

Last Name

Ahmed

MiddleName

-

Affiliation

-

Email

-

City

-

Orcid

-

Volume

85

Article Issue

1

Related Issue

27163

Issue Date

2021-10-01

Receive Date

2021-09-11

Publish Date

2021-10-01

Page Start

3,092

Page End

3,097

Print ISSN

1687-2002

Online ISSN

2090-7125

Link

https://ejhm.journals.ekb.eg/article_194063.html

Detail API

https://ejhm.journals.ekb.eg/service?article_code=194063

Order

71

Type

Original Article

Type Code

606

Publication Type

Journal

Publication Title

The Egyptian Journal of Hospital Medicine

Publication Link

https://ejhm.journals.ekb.eg/

MainTitle

Accuracy of Optic Nerve Sheath Diameter Measurement as a Predictor of Intracranial Pressure in Traumatic Brain Injury

Details

Type

Article

Created At

22 Jan 2023