Purpose: To assess the diagnostic accuracy of multi-detector CT angiography in the assessment of lower extremity arterial diseases by comparing the results with thestandard of reference, conventional angiography. Patients and Methods: The studied group included 140 patients with suspected diagnosis of lower limb arterial disease on the basis of clinical examination or Doppler study with no age or sex predilection between March 2011 and November 2013. All patients were evaluated with lower limb angiography by multi-detector computed tomography and conventional angiography. The data obtained was statistically analysed to assess the accuracy of diagnosis of lower limb arterial diseases by MDCT angiography compared to conventional angiography that described in terms of count and percentage. Results: MDCT angiography findings showed 90.3% overall agreement with CA findings regarding the degree of stenosis while regarding the stenosis length MDCT angiography results showed 87.5% overall agreement with CA results. The overall sensitivity of MDCT angiography was 94.5%, specificity was 92.2%, and accuracy was 95.3%.  Conclusion: Multi–detector row CT angiography can be used as an alternative to conventional angiography in the evaluation of aortoiliac and lower extremity arteries in patients with peripheral arterial disease.  

DOI

10.12816/0005578

Keywords

Computed tomography (CT), Conventional Angiography (CA), multi-detector computed tomography (MDCT)

Authors

First Name

Kareman M.

Last Name

Ahmed

MiddleName

-

Affiliation

Radiology Department, Faculty of Medicine, Ain Shams University, Cairo, Egypt

Email

-

City

-

Orcid

-

First Name

Sahar N.

Last Name

Mohamed

MiddleName

-

Affiliation

Radiology Department, Faculty of Medicine, Ain Shams University, Cairo, Egypt

Email

-

City

-

Orcid

-

First Name

Sherif H.

Last Name

Abo Gamra

MiddleName

-

Affiliation

Radiology Department, Faculty of Medicine, Ain Shams University, Cairo, Egypt

Email

-

City

-

Orcid

-

First Name

Nivine A.

Last Name

Chalabi

MiddleName

-

Affiliation

Radiology Department, Faculty of Medicine, Ain Shams University, Cairo, Egypt

Email

-

City

-

Orcid

-

Volume

57

Article Issue

1

Related Issue

3358

Issue Date

2014-10-01

Receive Date

2018-10-01

Publish Date

2014-10-01

Page Start

311

Page End

320

Print ISSN

1687-2002

Online ISSN

2090-7125

Link

https://ejhm.journals.ekb.eg/article_15541.html

Detail API

https://ejhm.journals.ekb.eg/service?article_code=15541

Order

6

Type

Original Article

Type Code

606

Publication Type

Journal

Publication Title

The Egyptian Journal of Hospital Medicine

Publication Link

https://ejhm.journals.ekb.eg/

MainTitle

Diagnostic Accuracy of Multi-detector CT Angiography in Evaluation of Lower Limb Arterial Diseases: Comparative Study with Conventional Angiography

Details

Type

Article

Created At

22 Jan 2023