Abstract

Background: sysmex XT 1800i coulter is a hematology analyzer incorporating new electronic and mechanical design with advanced algorithm technology to perform CBC. The principles of sysmex XT1800 are electrical impedance technology, optical scatter technology, flow cytometry. The sysmex XT-1800i haematology  analyser is used in unique fluorescence flow cytometry (FFC) technology. FFC looks at deoxyribonucleic acid (DNA) content, cell size and inner cell complexity rather than cell size alone. This generates remarkably accurate results. Review rates and turnaround time are reduced due to specific fluorochrome labelling. The XT-1800i offers true quantitative immunoglobulin ( IG) counting instead of the flagging delivered by other technologies.  Patiant and Method: Evaluation of this instrument was performed on 200 samples of inpatient and outpatient people in Ain Shams University Hospitals. We collected samples from all departments of the hospital randomly of any age and sex except those of age less than 18 years old. Results : this study was centered upon RBCs indices which were  mean corpuscular volume (MCV),mean corpuscular hemoglobin(MCH),red cell distribution width (RDW) after comparing sysmex XT 1800 coulter results  for RBCs parameters with  morphology  by smear review under the microscope. We found that the device sensitivity was 74.7%  , 75 % ,83 % and specificity was 74.3% , 79.5 % ,78.7%  according to RBCs size ,chromasia and anaesocytosis respectively. Conclusion: at the end of our study we reached to specific criteria at which we must do a blood film smear review to evaluate RBCs abnormalities which cannot be evaluated by the device.  

DOI

10.12816/0039674

Keywords

hematology analyzer, abnormal RBCs morphology

Authors

First Name

Tahany Ali

Last Name

El Kerdany

MiddleName

-

Affiliation

Department of Clinical and Chemical Pathology, Faculty of Medicine, Ain shams University

Email

-

City

-

Orcid

-

First Name

Soha

Last Name

Abo El Ela

MiddleName

-

Affiliation

Department of Clinical and Chemical Pathology, Faculty of Medicine, Ain shams University

Email

-

City

-

Orcid

-

First Name

Janette Botros Shoukry

Last Name

Aziz

MiddleName

-

Affiliation

Department of Clinical and Chemical Pathology, Faculty of Medicine, Ain shams University

Email

dr_janet5889@hotmail.com

City

-

Orcid

-

Volume

68

Article Issue

3

Related Issue

2617

Issue Date

2017-07-01

Receive Date

2018-09-14

Publish Date

2017-07-01

Page Start

1,358

Page End

1,363

Print ISSN

1687-2002

Online ISSN

2090-7125

Link

https://ejhm.journals.ekb.eg/article_13587.html

Detail API

https://ejhm.journals.ekb.eg/service?article_code=13587

Order

9

Type

Original Article

Type Code

606

Publication Type

Journal

Publication Title

The Egyptian Journal of Hospital Medicine

Publication Link

https://ejhm.journals.ekb.eg/

MainTitle

Study of Automated Red Blood Cells Parameters in Correlation with Routine RBCs Morphology by Smear Review

Details

Type

Article

Created At

22 Jan 2023