Beta
11853

Comparison between Corneal Biomechanics in Normal and Keratoconic Corneas Using Ocular Response Analyzer

Article

Last updated: 24 Dec 2024

Subjects

-

Tags

-

Abstract

Background: keratoconus (KC) is an idiopathic degenerative eye disease characterized by localized thinning and conical protrusion of the cornea, which typically develops in the inferior-temporal and central zones. Consequently, visual acuity is reduced due to irregular astigmatism and high myopia resulting from asymmetric topographical changes in the corneal surface. KC is the most prevalent form of corneal ectasia and affects all ethnicities. However, higher incidence has been reported in Asians when compared to caucasians. Aim of the work: this study aimed to compare the biomechanical properties of the cornea between topographically normal individuals with topographically keratoconic patients. Patients and methods: this prospective study was carried out from January 2017 to July 2017 on 40 eyes of patients attending outpatient clinic of Ain Shams University Hospitals and Ophthalmology Department of Research Institute of Ophthalmology in Giza. All participant names were hidden and were replaced by code numbers to maintain privacy of the patients. Ocular response analyzer (ORA) values were obtained from 20 eyes of keratoconus patients and 20 eyes of non keratoconus subjects both topographically tested. Results: corneal hysteresis (CH) was found to be higher in normal group than keratoconus group; the values were found to be 10.9 ± 1.5 in normal group and 7.88 ± 1.23 in keratoconus group. Corneal resistance factor (CRF) was found to be higher in normal group than keratoconus group, the values were found to be 12.7 ± 1.05 in normal group and 6.7 ± 1.7 in keratoconus group. Goldmann correlated intraocular pressure (ORA_IOPg) was found to be higher in normal group than keratoconus group, the values were found to be 13.13 ± 2.91 in normal group and 10.31 ± 2.99 in keratoconus group. Corneal compensated intraocular pressure (ORA_IOPcc) was found to be 14.17 ± 3.44 in normal group and 14.23 ± 2.01 in keratoconus group, there was no difference between normal group and keratoconus group. Conclusion: corneal biomechanical properties, characterized by corneal hysteresis and the corneal resistance factor, provide new indicators for the diagnosis of keratoconus. Recommendations: this study recommended to follow up IOP in keratoconus patients by ORA due to false low results which may be taken by using the Goldman applanation intraocular pressure. Large studies should be done to detect the prevelance of keratoconus in Egypt as this information was missing from peerviewed studies we researched.  

DOI

10.12816/0041515

Keywords

corneal biomechanics, keratoconic corneas, ocular response, topographically, Corneal Hysteresis

Authors

First Name

Shaker A.

Last Name

Khedr

MiddleName

-

Affiliation

Ophthalmology Department, Faculty of Medicine, Ain Shams University

Email

-

City

-

Orcid

-

First Name

Amany A.

Last Name

El-Shazly

MiddleName

-

Affiliation

Ophthalmology Department, Faculty of Medicine, Ain Shams University

Email

-

City

-

Orcid

-

First Name

Ossama T.

Last Name

Nada

MiddleName

-

Affiliation

Ophthalmology Department, Faculty of Medicine, Ain Shams University

Email

-

City

-

Orcid

-

First Name

Kareem A.

Last Name

Abouelezz

MiddleName

-

Affiliation

Ophthalmology Department, Faculty of Medicine, Ain Shams University

Email

kareem.ezz1@hotmail.com

City

-

Orcid

-

Volume

69

Article Issue

4

Related Issue

2178

Issue Date

2017-10-01

Receive Date

2018-08-28

Publish Date

2017-10-01

Page Start

2,191

Page End

2,198

Print ISSN

1687-2002

Online ISSN

2090-7125

Link

https://ejhm.journals.ekb.eg/article_11853.html

Detail API

https://ejhm.journals.ekb.eg/service?article_code=11853

Order

2

Type

Original Article

Type Code

606

Publication Type

Journal

Publication Title

The Egyptian Journal of Hospital Medicine

Publication Link

https://ejhm.journals.ekb.eg/

MainTitle

Comparison between Corneal Biomechanics in Normal and Keratoconic Corneas Using Ocular Response Analyzer

Details

Type

Article

Created At

22 Jan 2023