Beta
235371

Impact of Locator Attachments with Different Retentive Insert Materials on Bite Force in Mandibular Implant Overdenture

Article

Last updated: 03 Jan 2025

Subjects

-

Tags

-

Abstract

.Purpose: To evaluate the impact of locator attachments with different retentive insert materials on bite force in mandibular
implant overdenture.
Materials and Methods: Eight completely edentulous patients were selected for this study. Each patient received two implants
in the canine area of the mandible bilaterally. Patient grouping was performed as follow, group Ι: 4 patients received two locator
overdenture attachments with nylon inserts, group ΙΙ: 4 patients received two locator overdenture attachments with PEEK
inserts. The bite force was measured with conventional complete denture, after 3 months of overdenture insertion and after 6
months using occlusal force transducer. The surface wear evaluation of PEEK and nylon inserts were done before pick-up, after
3 months and after 6 months of overdenture insertion using scanning electron microscope (SEM).
Results: There was significant difference between groupI(nylon insert) and groupII (PEEK insert).Overdentures loaded
with PEEK inserts recorded significant increase in bite force values than nylon inserts after 3 months and 6 months of
overdenture insertion(P<0.001). Significant wear changes were shown with nylon inserts at (T3) and (T6) rather than PEEK
inserts(P<0.001).
Conclusion:PEEK inserts in locator attachments provide successful inserts instead of nylon ones providing better biteforce and
wear resistence

DOI

10.21608/omx.2022.109075.1145

Keywords

Implant overdenture, PEEK insert, locator, biteforce

Authors

First Name

Abdelaziz

Last Name

M.

MiddleName

-

Affiliation

Department of Prosthodontics, Faculty of Dentistry , Mansoura University , Egypt

Email

-

City

-

Orcid

-

First Name

Altonbary

Last Name

Y.

MiddleName

-

Affiliation

Department of Prosthodontics, Faculty of Dentistry , Mansoura University , Egypt

Email

-

City

-

Orcid

-

First Name

El Mekawy

Last Name

N.

MiddleName

-

Affiliation

Department of Prosthodontics, Faculty of Dentistry , Mansoura University , Egypt

Email

-

City

-

Orcid

-

First Name

Hegazy

Last Name

A.

MiddleName

-

Affiliation

Department of Prosthodontics, Faculty of Dentistry , Mansoura University , Egypt

Email

-

City

-

Orcid

-

Volume

12

Article Issue

4

Related Issue

33912

Issue Date

2021-10-01

Receive Date

2021-12-01

Publish Date

2021-10-01

Page Start

245

Page End

254

Print ISSN

2090-097X

Online ISSN

2090-5424

Link

https://omx.journals.ekb.eg/article_235371.html

Detail API

https://omx.journals.ekb.eg/service?article_code=235371

Order

3

Type

Original Article

Type Code

506

Publication Type

Journal

Publication Title

Egyptian Journal of Oral and Maxillofacial Surgery

Publication Link

https://omx.journals.ekb.eg/

MainTitle

Impact of Locator Attachments with Different Retentive Insert Materials on Bite Force in Mandibular Implant Overdenture

Details

Type

Article

Created At

22 Jan 2023