Beta
230069

“The Accuracy of Mimic Software compared to AutoCAD Software in The Evaluation of the Volumetric Reduction of Maxillofacial Cystic Lesions after Marsupialization: A prospective c

Article

Last updated: 23 Dec 2024

Subjects

-

Tags

-

Abstract

Background: tA growing body of evidence has recently utilized 3D assessment to follow up on the volume reduction after
marsupialization of maxillofacial cysts and the need for enucleation. Materialise Mimics software has been widely used for
that purpose. Recently, computer-aided design (AutoCAD) has proven its reliability in assessing the change in cyst volume in
a wide range of surgeries.
Purpose: To compare the accuracy of two computer programs (commercial computer-aided design (AutoCAD) and Materialise
Mimics) in measuring the volume reduction of cysts post marsupialization.
Materials and Methods: We conducted a case-series study on 15 patients with radicular cysts who underwent marsupialization.
The determination of cyst measured volume was carried out using AutoCAD and Mimics pre-operatively and up to nine months
after the procedure.
Results: Using AutoCAD software, the volume (mm3) estimated and average (±SD) of 29037.9,13759.9±10137.8 ,94.994±
3303.7±1984.4 ,4579.1±3276.6 mm3 in pre-marsupialization, 3-, 6-, and 9-months post-marsupialization; respectively. With
Mimics software, the volume (mm3) recorded an average (SD) of 29041.04579.0±3275.0 ,13761.4±10144.6 ,94994.5±, and
1984.63303.9± mm3 in pre-marsupialization, 3-, 6-, and 9-months post-marsupialization; respectively. The difference between
measures carried out by MIMIC and AutoCAD software was non-significant (p>0.05) at all checked follow-up time points (pre-
, 3-, 6-, 9- months post-marsupialization)
Conclusion: Computer-aided (AutoCAD) assessment of post-marsupialization volume reduction of maxillofacial cysts is a
readily available, easy-to-use, cheap, and accurate option to be contemplated along with Mimics software.

DOI

10.21608/omx.2021.81557.1121

Keywords

Cystic lesions, marsupialization, AutoCAD, Mimics

Authors

First Name

Mohamed

Last Name

Ghoneim

MiddleName

-

Affiliation

Department of Oral and Maxillofacial Surgery Faculty of Dentistry Sinai University

Email

mohamed.moawed@su.edu.eg

City

-

Orcid

0000-0002-1975-3067

First Name

Hamed

Last Name

Gad

MiddleName

-

Affiliation

Department of Oral and Maxillofacial Surgery Faculty of Dentistry Minia University

Email

-

City

-

Orcid

-

Volume

12

Article Issue

3

Related Issue

32940

Issue Date

2021-07-01

Receive Date

2021-06-20

Publish Date

2021-07-01

Page Start

205

Page End

215

Print ISSN

2090-097X

Online ISSN

2090-5424

Link

https://omx.journals.ekb.eg/article_230069.html

Detail API

https://omx.journals.ekb.eg/service?article_code=230069

Order

6

Type

Original Article

Type Code

506

Publication Type

Journal

Publication Title

Egyptian Journal of Oral and Maxillofacial Surgery

Publication Link

https://omx.journals.ekb.eg/

MainTitle

“The Accuracy of Mimic Software compared to AutoCAD Software in The Evaluation of the Volumetric Reduction of Maxillofacial Cystic Lesions after Marsupialization: A prospective comparative study.”

Details

Type

Article

Created At

22 Jan 2023