Abstract

Muslims from all over the world have grown familiar with the traditional sight of the Holy land on mount Mina and Arafat during the Hajj for hundreds of years; the view of the tents established in those areas has become the memorable, architectural style and an unchangeable heritage legacy of this yearly Islamic event. However, following trends showing yearly exponential increase in the number of pilgrims recently imposed the greatest challenge for operators and organizers of the pilgrimage. A proposal addressing the inevitable need to preserve the historical urban/ architectural context of Mina and Arafat, underground accommodations represent an imminent solution. Optimizing natural lighting, ventilation and air conditioning for underground accommodations are key parameters for an efficient and sustainable upgrade for the holy lands. This paper presents a Parans fiber optics, natural light transfer system integration designed to enhance daylight performance in Hajj underground proposed habitational spaces. The proposed upgrade aims to align with both “LEED V4" and the “IES Daylight availability" standards. The natural “daylighting analysis" is performed using ‘Radiance' for a generic room. Firstly, architectural design and technical system integration details are presented for the proposed underground accommodations. Secondly, the effect of fiber optics' system design on the space, lighting performance and energy efficiency is parametrically optimized and compared to the performance of traditional lighting, windows for a range of window to wall ratios (WWR) of equivalent mid-story high-rise south-facing spaces as reference base cases. Results demonstrate that Parans system integration achieved comparable results which meet “LEED v4" caliber and exceeds the “IES Daylight availability" criterions. Upgrading to multi-story underground residential spaces can maintain the historic contextual image of tents while reducing heat transferred through the envelope by 200 kWh/m2 annually and reduce cooling loads components by 80% decreasing the CO2 emissions monthly by 500–600 kg per unit.
 

DOI

10.21608/jes.2018.21777

Keywords

Daylighting, Sustainability, Underground accommodation, Ventilation, heritage preservation, Green Urbanism

Authors

First Name

El-Hamouly,

Last Name

Nothiela, A

MiddleName

-

Affiliation

Faculty of Engineering, Shubra, Banha University

Email

-

City

-

Orcid

-

Volume

41

Article Issue

3

Related Issue

4172

Issue Date

2018-03-01

Receive Date

2018-03-12

Publish Date

2018-03-01

Page Start

117

Page End

150

Print ISSN

1110-0826

Online ISSN

2636-3178

Link

https://jes.journals.ekb.eg/article_21777.html

Detail API

https://jes.journals.ekb.eg/service?article_code=21777

Order

6

Type

Review Article

Type Code

599

Publication Type

Journal

Publication Title

Journal of Environmental Science

Publication Link

https://jes.journals.ekb.eg/

MainTitle

-

Details

Type

Article

Created At

22 Jan 2023