Beta
7991

Comparative Study of Implant Supported Overdenture Retained with Two Types of Attachments

Article

Last updated: 22 Jan 2023

Subjects

-

Tags

-

Abstract

Objectives: This study was conducted to compare implant retained mandibular
overdenture with two different attachments (ball and socket and locator).
Subject and methods:7 edentulous patients were selected according to certain criteria.
Each patient received two platform switched implants placed in the mandibular canine-premolar region bilaterally. GROUP I: Locator attachments were used to retain the implant-supported overdentures. Locator abutments were loaded after 2-3 months. All patients received conventional maxillary dentures. After follow up periods we removed
the attachment with wash period 1month then we used ball and socket attachment
GROUP II. The two groups were evaluated for retention, masticatory efficiency and EMG at 0, 3 and 6 months after loading of each attachment. Results: regarding the effect of time on retention of both groups in ball group there was a significant increase in retention at base line till 3 months and decrease from 3-6 months, while locator group there was increase of retention through all periods. Regarding the effect of time on both groups the masticatory efficiency of both ball and locator group have no significant difference through all periods. Comparing the two groups the masticatory efficiency has no significant difference except on chewing carrots the numbers of strokes till first swallow increase in ball group, and on chewing peanut after 6 months the ball group show higher time till first swallow than locator as well as the time to empty mouth. Regarding the effect of time on both groups the electromyographic activity of both masseter
and temporalis muscles has no significant difference through all periods except in locator group decrease the activity of masseter after 3 months. Conclusions: the ball attachment at the beginning has a higher retention quality than locator attachment, by time ball attachment loss some of its retention rather than locator attachment. The electromyographic activities and the masticatory efficiency of temporalis and masseter muscles of both ball attachment and locator attachment were comparable.

DOI

10.21608/adjg.2018.7991

Keywords

Implant overdenture attachment

Authors

First Name

Sarah

Last Name

Elqady

MiddleName

-

Affiliation

Post graduate student, Department of Removable Prosthodontics, Faculty of Dental Medicine, El -Azhar University, for girls.

Email

-

City

-

Orcid

-

First Name

Amany

Last Name

Abd El-Fatah

MiddleName

-

Affiliation

Professor of Prosthodontics, the Vice Dean of Faculty of Dental Medicine, El-Azhar University, for girls.

Email

-

City

-

Orcid

-

First Name

Nesreen

Last Name

El-Mahrouky

MiddleName

-

Affiliation

Professor of Prosthodontics, the head of prosthodontic Dept., Faculty of Dental Medicine, El-Azhar University, for girls.

Email

-

City

-

Orcid

-

Volume

5

Article Issue

1

Related Issue

1540

Issue Date

2018-01-01

Receive Date

2018-06-10

Publish Date

2018-01-01

Page Start

37

Page End

46

Print ISSN

2537-0308

Online ISSN

2537-0316

Link

https://adjg.journals.ekb.eg/article_7991.html

Detail API

https://adjg.journals.ekb.eg/service?article_code=7991

Order

6

Type

Original Article

Type Code

488

Publication Type

Journal

Publication Title

Al-Azhar Dental Journal for Girls

Publication Link

https://adjg.journals.ekb.eg/

MainTitle

-

Details

Type

Article

Created At

22 Jan 2023