This study assessed the clinical usefulness of the 2D-Array Seven29 ,which may compensate for the of the water phantom, by comparing the radiological doses between the two depending on five field sizes. The experimental equipment used was a linear accelerator for medical use, treatment planning system (TPS) , water phantom, 2D-Array, solid phantoms,( Semiflex , Pinpoint) types ion chamber and electrometer. The field size was 10 x 10 cm2 and the radiation energies of the photon beam were 6 MV and 15 MV, The field size involved (1×1, 2×2, 3×3, 4×4, 5×5,) for each energy. The relative deviation ratio of the TPS to both chamber in water phantom and TPS to 2darray in the solid phantom was calculated. The measured doses in standard phantom were less than the TPS values for small field dimensions for fields less than 3×3 cm2, The measured data by 2D-Array data for fields 2×2 and 3×3cm2 this difference within ±2% is due to good accuracy of measurement planning system for field size 1×1cm2. The measured in standard phantom were less than the TPS values for small field dimensions and the measured data by 2D-Array for 6 MV shows mild differences between the TPS and the experimental data. Small difference existed between the TPS and the experimental data using 2D-Array for 15 MV the results were the same for TPS and measured data, at only field dimension of 1×1cm2. Measured data was increased as field area enlarged from 2×2 to 5×5cm2 by constant value of 4%.

DOI

10.21608/ajnsa.2019.13053.1217

Keywords

2D-Array seven29, Photon Beam Dose, Small Field sizes, Treatment Planning System

Authors

First Name

Sherihan

Last Name

Hassan

MiddleName

-

Affiliation

National Cancer Institute (NCI), Cairo University, Cairo, Egypt

Email

shhassan148@yahoo.com

City

-

Orcid

0000-0003-3304-0781

First Name

Arafa

Last Name

Aly

MiddleName

-

Affiliation

TH-PPM Group, Physics Department, Faculty of Sciences, Beni-Suef University, Egypt

Email

arafaaly@aucegyt.edu

City

-

Orcid

-

First Name

Nashaat

Last Name

Deiab

MiddleName

-

Affiliation

Cairo University

Email

eg.mrs.2030@gmail.com

City

-

Orcid

-

Volume

53

Article Issue

1

Related Issue

10143

Issue Date

2020-01-01

Receive Date

2019-05-22

Publish Date

2020-01-01

Page Start

119

Page End

124

Print ISSN

1110-0451

Online ISSN

2090-4258

Link

https://ajnsa.journals.ekb.eg/article_65864.html

Detail API

https://ajnsa.journals.ekb.eg/service?article_code=65864

Order

12

Type

Original Article

Type Code

455

Publication Type

Journal

Publication Title

Arab Journal of Nuclear Sciences and Applications

Publication Link

https://ajnsa.journals.ekb.eg/

MainTitle

Comparative Study and Dose Evaluation of Photon Beam for water phantom,2D-array and Treatment Planning System in Small Field sizes

Details

Type

Article

Created At

22 Jan 2023