Beta
76518

Highly sensitive electrochemical sensor determination of drug in pharmaceutical analysis

Article

Last updated: 22 Jan 2023

Subjects

-

Tags

Inorganic chemistry

Abstract

Modified carbon paste electrodes and screen printed electrodes were developed for the potentiometric determination of butenafine hydrochloride (BTFHC) in urine, serum and pharmaceutical preparations. Two modified carbon paste electrodes (electrodes A and C) and two modified screen printed electrodes (electrodes B and D) using tricresylphosphate (TCP) and
o-nitrophenyloctyl ether (o-NPOE) plasticizers, respectively, were used. The electrodes showed a linear concentration range from 1.57×10-7 to 1.0 × 10-2 and 1.0 × 10-7 to 1.0 × 10-2 mol L-1 with detection limit of 1.57×10-7 and 1.0 × 10-7 mol L-1 for modified carbon paste (MCPEs; electrodes A and B) and modified screen printed (MSPEs; electrodes C and D), respectively. The calibration graphs have slope values of 56.95±0.56, 58.22±0.78, 56.18±0.66 and 57.69±0.39 mV decade-1 for electrodes A, B, C and D, respectively. The response time was relatively quick in the whole concentration range and was found to be 12s for electrodes (A and B) and 7s for electrodes (C and D). The electrodes were found to have life time of 82, 99, 160 and 185 days without showing any deviations in a pH range of 5.0–9.0 and 4.0–9.0 for MCPEs (electrodes A and B) and MSPEs electrodes (C and D), respectively. The fabricated electrodes displayed good selectivity for BTFHC with respect to number of common foreign inorganic cations, sugar species, organic and glycine as the fillers that may be added to the pharmaceutical preparation or biological fluids. Fortunately, such materials mostly do not interfere. The potential application of the sensors (A-D) was accomplished as a result of good recoveries made from real samples fortified with BTFHC. Results indicated the proficiency of the sensors reliable for rapid, onsite monitoring of BTFHC in pharmaceutical preparation and in biological samples.

DOI

10.21608/ejchem.2020.24925.2479

Keywords

Butenafine hydrochloride ion-selective electrodes, Modified carbon paste electrode, Modified screen-printed sensors, Pharmaceutical analysis, Potentiometric Determination

Authors

First Name

Tamer Awad

Last Name

Ali

MiddleName

-

Affiliation

Egyptian Petroleum Research Institute (EPRI), 11727, Cairo, Egypt.

Email

dr_tamerawad@hotmail.com

City

Nasr City

Orcid

0000-0002-5897-0005

First Name

Gehad

Last Name

Mohamed

MiddleName

G.

Affiliation

Chemistry, Faculty of Science, Cairo University

Email

ggenidy68@hotmail.com

City

Nasr City

Orcid

-

First Name

Dina

Last Name

Abdeen

MiddleName

-

Affiliation

Chemistry, Faculty of Science, Cairo University

Email

dodaabdeen36@gmail.com

City

Giza

Orcid

-

First Name

Hassan

Last Name

El-Dessouky

MiddleName

-

Affiliation

Chemistry Department, Faculty of Science, Banha University, 13518, Qalubia, Egypt.

Email

moonsky050@yahoo.com

City

-

Orcid

-

Volume

63

Article Issue

8

Related Issue

10594

Issue Date

2020-08-01

Receive Date

2020-02-29

Publish Date

2020-08-01

Page Start

2,933

Page End

2,946

Print ISSN

0449-2285

Online ISSN

2357-0245

Link

https://ejchem.journals.ekb.eg/article_76518.html

Detail API

https://ejchem.journals.ekb.eg/service?article_code=76518

Order

12

Type

Original Article

Type Code

297

Publication Type

Journal

Publication Title

Egyptian Journal of Chemistry

Publication Link

https://ejchem.journals.ekb.eg/

MainTitle

-

Details

Type

Article

Created At

22 Jan 2023