216784

In screening breast program: Can automated breast ultrasound (ABUS) have a role in the future?

Article

Last updated: 01 Jan 2025

Subjects

-

Tags

Radiodiagnosis

Abstract

Background; Recent imaging modality named automated breast ultrasound encountered for mammographic substitution. Aim of our study to compare ABUS and mammography as screening modality with special concern to dense breasts.
Method; Eighty participants from our breast screening program examined with mammography and ABUS. The study was carried out during the period from September 2020 to October 2021.
Results; The percentage of BIRAD II and BIRAD III detected lesions in mammogram was 31.25% and 12.5%, while, in ABUS, it increased to 32.5% and 11.25%, respectively. Also, the percentage of BIRAD IV and BIRAD V detected lesions in mammogram was 20% and 11.25%, while, in ABUS, it increased to 22.5% and 12.5%, respectively; thus, ABUS is a useful tool in detection of benign, probably benign and malignant lesions compared to mammogram. The added value of ABUS over mammography in picking breast lesions was most noted in participants with dense and extremely dense breasts as a statistically significant difference was found. The sensitivity of the ABUS is about 100%, and that means, in all the results of the mammogram study, ABUS can detect it without significant change, while the specificity of the ABUS was about 85%.
Conclusion; ABUS is a scientific improvement in breast radiology with the advantage of innovative diagnostic precision of breast pathologies in terms of initial recognition, better classification, and meticulous evaluation. It is operator independent, saving time, and permits whole breast assessment with no radiation hazard, improved picking of few millimeters' pathologies particularly in dense breast parenchyma.

DOI

10.21608/zumj.2022.106130.2409

Keywords

Mammography, Automated breast ultrasound, dense breast

Authors

First Name

Elshaimaa

Last Name

Mohamed

MiddleName

-

Affiliation

Radiodiagnosis department faculty of medicine Zagazig university Zagazig Egypt

Email

bosy.radiology@gmail.com

City

Zagazig

Orcid

-

First Name

Ali

Last Name

Hassanin

MiddleName

M.

Affiliation

radiology department, faculty of medicine, zagazig university, Zagazig, Egypt

Email

dr_alih2000@hotmail.com

City

Zagazig

Orcid

0000-0001-8634-969x

First Name

Mona

Last Name

Refaat

MiddleName

Mohammed

Affiliation

radiodiagnosis,faculty of medicine,zagazig university,egypt

Email

refaatmona96@gmail.com

City

zagazig

Orcid

-

Volume

28

Article Issue

6

Related Issue

37452

Issue Date

2022-11-01

Receive Date

2021-11-15

Publish Date

2022-11-01

Page Start

1,214

Page End

1,221

Print ISSN

1110-1431

Online ISSN

2357-0717

Link

https://zumj.journals.ekb.eg/article_216784.html

Detail API

https://zumj.journals.ekb.eg/service?article_code=216784

Order

5

Type

Original Article

Type Code

273

Publication Type

Journal

Publication Title

Zagazig University Medical Journal

Publication Link

https://zumj.journals.ekb.eg/

MainTitle

In screening breast program: Can automated breast ultrasound (ABUS) have a role in the future?

Details

Type

Article

Created At

22 Jan 2023