Beta
81099

Tolerable Versus Classic Endotracheal Tube Effect on Hemodynamic Response During Extubation: Comparative Study

Article

Last updated: 01 Jan 2025

Subjects

-

Tags

Anaesthesia & Surgical Intensive Care

Abstract

Background: The process of laryngoscopy, endotracheal intubation and extubation is usually associated with exaggerated hemodynamic response including, hypertension, tachycardia, increased intracranial and intraocular pressure. The aim of this study was to evaluate and compare effectiveness of the modified tolerable endotracheal tube TET with the classical one in relation to hemodynamic response during extubation in patients under general anesthesia. Patients and Methods: Sixty patients with physical status American Society of Anesthesiologists ASA I, II aged 21–60 years, scheduled to undergo elective laparoscopic cholystectomy. The patients were randomly divided into 2 groups (30 each), group C: Classic Endotracheal Tube (classic group) and group T: Tolerable endotracheal tube (TET); that receiving intratracheal 7ml 0.5% Bupivacaine. Hemodynamic parameters; Blood pressure (systolic, diastolic mean blood pressure) were evaluated during the extubation. Results: Classic group showed significantly higher HR than tolerable group at 10 & 20 min P =0.031, P = 0.025 respectively, at extubation P=0.001 and 3min post extubation p = 0.003. Regarding MBP, group C showed significantly higher reading than group T at 20 min P=0.032 after induction and at extubation time P=0.002. Conclusion: Spraying intratracheal 7 ml of bupivacaine 0.5mg via TET can decrease the incidence of complications in the form of hemodynamic instability on emergence from general anesthesia GA.

DOI

10.21608/zumj.2020.23346.1718

Keywords

Tolerable endotracheal tube, Bupivacaine, Hemodynamic response, Extubation

Authors

First Name

Osama

Last Name

Nofal

MiddleName

Abd Elgawad

Affiliation

Department of Anesthesia and surgical intensive care, Faculty of Medicine – Zagazig University, Egypt

Email

onofall@medicine.zu.edu.eg

City

-

Orcid

-

First Name

Abeer

Last Name

Elsawy

MiddleName

hassan

Affiliation

Department of Anesthesia and surgical intensive care, Faculty of Medicine – Zagazig University, Egypt

Email

absawy2@hotmail.com

City

zagazig

Orcid

-

First Name

MUSTAFA

Last Name

Hokoma

MiddleName

-

Affiliation

Department of Anesthesia and surgical intensive care, Faculty of Medicine – Almergeb University,Libya

Email

mustafahokoma654@gmail.com

City

Zagazig

Orcid

-

First Name

Marwa

Last Name

Medhat

MiddleName

Mohamed

Affiliation

Department of Anesthesia and surgical intensive care, Faculty of Medicine – Zagazig University, Egypt

Email

medhatmarwa9@gmail.com

City

-

Orcid

-

Volume

28

Article Issue

4

Related Issue

35321

Issue Date

2022-07-01

Receive Date

2020-02-03

Publish Date

2022-07-01

Page Start

897

Page End

903

Print ISSN

1110-1431

Online ISSN

2357-0717

Link

https://zumj.journals.ekb.eg/article_81099.html

Detail API

https://zumj.journals.ekb.eg/service?article_code=81099

Order

34

Type

Original Article

Type Code

273

Publication Type

Journal

Publication Title

Zagazig University Medical Journal

Publication Link

https://zumj.journals.ekb.eg/

MainTitle

Tolerable Versus Classic Endotracheal Tube Effect on Hemodynamic Response During Extubation: Comparative Study

Details

Type

Article

Created At

22 Jan 2023