76634

Comparative Study between Pentacam and IOL Master in Measuring Anterior Segment Parameters in Eyes of Egyptian Individuals

Article

Last updated: 01 Jan 2025

Subjects

-

Tags

-

Abstract

Abstract
Background: Accurate values of anterior segment param-eters are important for diagnosing variety of diseases and for cataract surgery, glaucoma, refractive surgery and post-operative follow-up. The true values of Anterior Chamber Depth (ACD), corneal power (K-readings) and White-to-White (WTW) are essential in calculating the Intraocular Lens power (IOL). The measurement of the ACD and WTW is essential for the success of phakic IOL implantation in patients asking for refractive surgery. This is now possible because of the development of new, accurate diagnostic and surgical tools.
Aim of Study: To compare values of anterior segment parameters (ACD, K-reading, WTW) obtained by Pentacam and IOL master to know if there are significant differences in measurement results between both devices or only minimal differences which can be neglected.
Patients and Methods: This comparative cross sectional study included 40 eyes of 22 Egyptian individuals. Evaluation included best corrected visual acuity, slit-lamp evaluation and autorefractometer reading. Imaging by investigative method in the form of IOL master 500 and Pentacam Oculus. All investigations and examinations were done at Kobri El-Kobba military Hospital, Cairo. From January 2018 to August 2018.
Results: IOL master gives statistically significant higher value of K-readings (43.56±1.72 & 45.03±1.59 for K1 & K2 respectively) than Pentacam (43.28±1.73 & 44.72±1.58 for K1 & K2 respectively). Low significant difference between both devices in values of ACD (mean difference ± SD –0.03± 0.10). Pentacam measures longer WTW value (mean 12.10± 0.45) than IOL master (mean 12.00±0.41).
Conclusion: IOL master gives slightly higher K-reading than Pentacam. Both devices measure ACD accurately and give nearly similar results. IOL master gives reliable WTW estimation but pentacam measurement of WTW by inserting calipers on scheimpflug image may give different values than IOL master.

DOI

10.21608/mjcu.2019.76634

Keywords

Anterior chamber depth – White-to-White – K- readings – IOL master – Pentacam

Authors

First Name

ALI H. SAAD, M.D.;

Last Name

THANAA HELMY, M.D.

MiddleName

-

Affiliation

-

Email

-

City

-

Orcid

-

First Name

YASSER EL-ZANKALONY, M.D.;

Last Name

MINA SAMEH, M.Sc.

MiddleName

-

Affiliation

The Department of Ophthalmology, Faculty of Medicine, Ain Shams University, Cairo, Egypt

Email

-

City

-

Orcid

-

Volume

87

Article Issue

December

Related Issue

11480

Issue Date

2019-12-01

Receive Date

2019-03-10

Publish Date

2019-12-01

Page Start

4,087

Page End

4,092

Print ISSN

0045-3803

Online ISSN

2536-9806

Link

https://mjcu.journals.ekb.eg/article_76634.html

Detail API

https://mjcu.journals.ekb.eg/service?article_code=76634

Order

9

Type

Original Article

Type Code

263

Publication Type

Journal

Publication Title

The Medical Journal of Cairo University

Publication Link

https://mjcu.journals.ekb.eg/

MainTitle

Comparative Study between Pentacam and IOL Master in Measuring Anterior Segment Parameters in Eyes of Egyptian Individuals

Details

Type

Article

Created At

22 Jan 2023