58065

Minimally Invasive Percutaneous Fixation of Non-United Scaphoid Fractures

Article

Last updated: 01 Jan 2025

Subjects

-

Tags

-

Abstract

Abstract
Background: Scaphoid non-unions pose a great challenge to surgeons because of the multiple factors that may contribute to their causation.
The etiology of the nonunion may be because of anatomic variations, fracture configuration, vascular problems, under-lying metabolic problems, or the inadequacy of initial treat-ment.
Percutaneous management of scaphoid non-unions offers the advantage of inducing minimal trauma to the soft tissues while adequately stabilizing the fracture site to induce union in a high percentage of cases.
This study proves that percutaneous fixation of delayed or nonunited scaphoid fractures result in predictable satisfactory union rate and functional outcome, it proves that percutaneous Herbert's screw insertion carries no risk of damage to soft tissues or vascular supply. Also, the gap is not the determinant of time to union but actually it is the time since injury; the longer the time since injury the longer the time to union as long as the scaphoid alignment is maintained i.e. no humpback deformity.

DOI

10.21608/mjcu.2018.58065

Keywords

Nonunion –Scaphoid –Headless screw–Percuta-neous

Authors

First Name

AHMED EL-XENI, M.Sc.;

Last Name

AHMED KHOLEIF, M.D.

MiddleName

-

Affiliation

-

Email

-

City

-

Orcid

-

First Name

SHERIF KHALED, M.D.;

Last Name

MOSTAFA MAHMOUD, M.D.

MiddleName

-

Affiliation

-

Email

-

City

-

Orcid

-

First Name

MOHAMED RAMADAN MOHAMED, M.Sc.;

Last Name

AHMED B. AL-SHAZLI, M.Sc.

MiddleName

-

Affiliation

-

Email

-

City

-

Orcid

-

First Name

ASHRAF

Last Name

YASSIN AMER, M.Sc.

MiddleName

-

Affiliation

The Department of Orthopedic Surgery, Faculty of Medicine, Cairo University

Email

-

City

-

Orcid

-

Volume

86

Article Issue

September

Related Issue

8755

Issue Date

2018-09-01

Receive Date

2017-11-10

Publish Date

2018-09-01

Page Start

2,615

Page End

2,620

Print ISSN

0045-3803

Online ISSN

2536-9806

Link

https://mjcu.journals.ekb.eg/article_58065.html

Detail API

https://mjcu.journals.ekb.eg/service?article_code=58065

Order

58

Type

Original Article

Type Code

263

Publication Type

Journal

Publication Title

The Medical Journal of Cairo University

Publication Link

https://mjcu.journals.ekb.eg/

MainTitle

Minimally Invasive Percutaneous Fixation of Non-United Scaphoid Fractures

Details

Type

Article

Created At

22 Jan 2023