Abstract
Background: The choroid is a highly vascular structure and it undergoes structural and functional alterations with increasing age which may affect the visual function. In addition, choroidal thickness differs according to the state of refraction and axial length.
Aim of the Study: To correlate between the subfoveal choroidal thickness and various clinical data including age, error of refraction, and best corrected visual acuity.
Patients and Methods: This cross sectional, non-randomized, non-controlled study was conducted on 124 eyes. Measurement of the subfoveal choroidal thickness was done using spectral domain optical coherence tomography in the Investigative and Laser Unit of the Ophthalmology Department of Kasr Al-Ainy Hospital.
Results: Results showed that thinner choroid was associ-ated with older age (r=–0.264, p-value=0.003) and myopic refraction (r=0.243, p-value=0.007), while thicker choroid was related to a better visual acuity (r=0.199, p-value=0.026). Also, there was no significant difference in choroidal thickness measurements by the two obsevers (p-value=0.161).
Conclusion: Older persons and eyes with myopic refraction have a thinner choroid. A thicker choroid is related to a better visual acuity. No inter-observer variation was found regarding choroidal thickness measurements.

DOI

10.21608/mjcu.2018.56557

Keywords

Subfoveal choroidal thickness – Age – Refractive error

Authors

First Name

SAFAA GALAL, M.Sc.;

Last Name

MOHAMMAD M. KHAFAGY, M.D.

MiddleName

-

Affiliation

-

Email

-

City

-

Orcid

-

First Name

HEBA M. AHMED, M.D.;

Last Name

SOHEIR M. ESMAT, M.D.

MiddleName

-

Affiliation

The Department of Ophthalmology, Faculty of Medicine, Cairo University

Email

-

City

-

Orcid

-

Volume

86

Article Issue

June

Related Issue

8539

Issue Date

2018-06-01

Receive Date

2017-11-02

Publish Date

2018-06-01

Page Start

1,679

Page End

1,681

Print ISSN

0045-3803

Online ISSN

2536-9806

Link

https://mjcu.journals.ekb.eg/article_56557.html

Detail API

https://mjcu.journals.ekb.eg/service?article_code=56557

Order

73

Type

Original Article

Type Code

263

Publication Type

Journal

Publication Title

The Medical Journal of Cairo University

Publication Link

https://mjcu.journals.ekb.eg/

MainTitle

Subfoveal Choroidal Thickness in Relation to Age and Refractive Error

Details

Type

Article

Created At

22 Jan 2023