Beta
267095

EVALUATION OF THE INTERNAL FIT OF PRESSABLE VERSUS CAD/CAM PEEK POST AND CORE USING SCANNING ELECTRON MICROSCOPE: AN IN VITRO STUDY

Article

Last updated: 22 Jan 2023

Subjects

-

Tags

Fixed Prosthodontics

Abstract

Aim: The study was conducted to evaluate the internal fit and marginal adaptation of custom-made Pressable compared to CAD/CAM PEEK post and core at three levels
Methodology: Twenty-eight extracted maxillary central incisors were prepared for custom post and cores. Acrylic resin patterns were fabricated and divided into two groups: CAD/CAM group: Resin patterns were directly scanned and milled from modified PEEK blocks and Press group: Patterns were pressed with granulate. Cement thickness was measured at four standardized points and the vertical marginal discrepancy was measured at twelve points using scanning electron microscope. One Way-ANOVA and Tukey`s post hoc test were performed to compare between the sections of each group; while Independent T-test was performed to compare between the two groups at different sections
Results: Regarding CAD/CAM group, the mean cement thickness was the highest in the coronal section (85.57±17.81) followed by the middle (72.87±18.57) then the apical (45.92±18.73). While for Press group, the middle section showed the highest mean cement thickness (50.99±15.98), followed by the coronal section (39.70±18.16), the apical section (21.37±4.30). Comparing between the two groups, CAD/CAM group had significantly higher internal gap in all sections (P=0.0001). Among cores marginal adaptation, no significant difference in means of all surfaces was revealed between the CAD/CAM (98.83±13.90) and press (95.08±13.91) groups (P=0.54)
Conclusion: Within the limitations of this study, pressed PEEK post and cores achieved superior internal fit compared to CAD/CAM. Neither CAD/CAM nor pressing technique influenced the marginal adaptation of PEEK cores and both were within the clinical acceptance range

DOI

10.21608/edj.2022.155151.2210

Keywords

CAD/CAM, Press, post and cores, internal fit, marginal adaptation

Authors

First Name

Shaimaa

Last Name

Naddar

MiddleName

-

Affiliation

BDS, 2014, Faculty of Dentistry, Misr International University, MSc Degree, Fixed Prosthodontics Department, Faculty of Dentistry, Cairo University

Email

shaimaa.ali@dentistry.cu.edu.eg

City

-

Orcid

0000-0002-6435-417X

First Name

Iman

Last Name

Hamdy

MiddleName

-

Affiliation

Professor, Fixed Prosthodontics Department, Faculty of Dentistry, Cairo University

Email

iman.salah@dentistry.cu.edu.eg

City

Cairo

Orcid

0000-0003-4548-2616

First Name

Maha

Last Name

Taymour

MiddleName

-

Affiliation

Associate Professor, Fixed Prosthodontics Department, Faculty of Dentistry, Cairo and New Giza University

Email

maha.taymour@dentistry.cu.edu.eg

City

-

Orcid

-

Volume

68

Article Issue

4

Related Issue

37372

Issue Date

2022-10-01

Receive Date

2022-08-08

Publish Date

2022-10-01

Page Start

3,671

Page End

3,682

Print ISSN

0070-9484

Online ISSN

2090-2360

Link

https://edj.journals.ekb.eg/article_267095.html

Detail API

https://edj.journals.ekb.eg/service?article_code=267095

Order

26

Type

Original Article

Type Code

254

Publication Type

Journal

Publication Title

Egyptian Dental Journal

Publication Link

https://edj.journals.ekb.eg/

MainTitle

-

Details

Type

Article

Created At

22 Jan 2023