267094

Influence Of Different Implant Abutment Connection On Fatigue Life Of Bone In Edentulous Hemimandibulectomy Cases Restored By Implant Supported Overdenture. A Finite Element Anal

Article

Last updated: 01 Jan 2025

Subjects

-

Tags

Removable Prosthodontics

Abstract

the purpose of the study is to compare the effect of different type of implant abutment connection system (external hexagonal, internal hexagonal and internal conical) of used implants under the overdenture in fatigue life of remaining bone of hemimandible.
Materials & methods: A three-dimensional finite element study model was constructed and duplicated three times. The model was composed of hemimandible screwed with reconstructive plate and restored by overdenture. The overdenture was retained by three implants of the same type of (IACS) at three positions. The only difference between the three models was the type of IACS used. Model (A) had implants of external hexagonal connection system, Model (B) had implants of internal hexagonal connection and model (C) had internal conical connection
Results: bone of internal hexagonal connection model showed largest number of fatigue life cycles, whereas external hexagonal connection showed smallest one and the values of internal conical connection model was intermediate
Conclusion: under the limitations of the current study, it may be concluded that using internal hexagonal IACS in implant supported mandibular overdenture rehabilitating hemimandible may be the most suitable type

DOI

10.21608/edj.2022.146338.2201

Keywords

Finite Element Analysis, implant abutment connection system, bone resorption, Stress distribution, Fatigue life

Authors

First Name

Reem

Last Name

Gamal

MiddleName

Eldien

Affiliation

Teaching Assistant Prosthetic Dentistry Department, Faculty of Dentistry, Minia University, Egypt

Email

ihelal89@gmail.com

City

Elminya

Orcid

0000-0003-0348-0962

First Name

Amr

Last Name

Badr

MiddleName

Mohamed Ismail

Affiliation

Associate Professor and Head of Prosthetic Dentistry Department, Faculty of Dentistry, Minia University, Egypt

Email

dr.amrbadr1972@gmail.com

City

-

Orcid

0000-0001-7233-2811

First Name

Emad

Last Name

Agamy

MiddleName

Mohammed

Affiliation

Professor, Prosthetic Dentistry Department, Faculty of Dentistry, Minia University, and Dean , faculty of Dentistry Delta University , Egypt

Email

emad_agamy@yahoo.com

City

Cairo

Orcid

0000-0003-4335-8005

Volume

68

Article Issue

4

Related Issue

37372

Issue Date

2022-10-01

Receive Date

2022-08-04

Publish Date

2022-10-01

Page Start

3,659

Page End

3,669

Print ISSN

0070-9484

Online ISSN

2090-2360

Link

https://edj.journals.ekb.eg/article_267094.html

Detail API

https://edj.journals.ekb.eg/service?article_code=267094

Order

25

Type

Original Article

Type Code

254

Publication Type

Journal

Publication Title

Egyptian Dental Journal

Publication Link

https://edj.journals.ekb.eg/

MainTitle

Influence Of Different Implant Abutment Connection On Fatigue Life Of Bone In Edentulous Hemimandibulectomy Cases Restored By Implant Supported Overdenture. A Finite Element Anal

Details

Type

Article

Created At

22 Jan 2023