Abstract

Background: One of the main objectives of the root canal treatment is the shaping and cleaning of the root canal without changing the outline of the root canal from the preoperative shape. Nickel Titanium files are some of tools used in producing proper cleaning and shaping of the canal. These files have different designs and type of motion that vary in its shaping and cleaning ability.
Objective: To evaluate the debris extrusion of dentin after the use of 3 different NiTi filling systems with different irrigations.
Materials and Methods: This study was concerned with comparing and evaluation the amount of apical extrusion of debris after preparation with three files systems using quantitative method by pre and post preparation weighting of the tubes collecting the apically extruded debris during the canal preparation.
Results: These results might be due to the viscosity of MTAD which is higher than hypochlorite. This may cause entrapment of the dentin debris inside the canal and prevent its extrusion from the apex and the great taper of M Pro files (25# .06 taper) with it's rotational movement so it touch all the canal walls with a great dentine removal.
Conclusion: In view of the results of the present study, the following conclusions can be drawn: Highest debris extrusion produced with using M-pro files. NaOCl produced more cleaning and shaping than MTAD than Saline. Lowest debris extrusion produced with using 2shape files.
Keywords: MTAD, M-PRO, PROTAPER, 2-SHAPE

DOI

10.21608/edj.2022.136671.2097

Keywords

MTAD, M-pro, ProTaper, 2-SHAPE

Authors

First Name

Yehia

Last Name

Ebeid

MiddleName

-

Affiliation

Department of Endodontics, Faculty of Dentistry, Ainshams University

Email

yehia.ebeid@gmail.com

City

-

Orcid

0000-0002-6247-1188

First Name

Medhat

Last Name

Elfaramawy

MiddleName

-

Affiliation

Endodontic Dep., Faculty of Dentistry, Ainshams University

Email

drmdht77@yahoo.com

City

cairo

Orcid

0000-0001-9131-5339

First Name

Tariq

Last Name

Yehia

MiddleName

-

Affiliation

Endodontic Dep., Faculty of Dentistry, Ainshams University

Email

tariqyehia@asfd.asu.edu.eg

City

-

Orcid

000000028574285x

Volume

68

Article Issue

3

Related Issue

36022

Issue Date

2022-07-01

Receive Date

2022-05-07

Publish Date

2022-07-01

Page Start

2,945

Page End

2,950

Print ISSN

0070-9484

Online ISSN

2090-2360

Link

https://edj.journals.ekb.eg/article_253235.html

Detail API

https://edj.journals.ekb.eg/service?article_code=253235

Order

21

Type

Original Article

Type Code

254

Publication Type

Journal

Publication Title

Egyptian Dental Journal

Publication Link

https://edj.journals.ekb.eg/

MainTitle

Debris Extrusion of Three Nickel-Titanium Rotary Instruments Using Different Irrigation Protocols (In Vitro Study)

Details

Type

Article

Created At

22 Jan 2023