252854

Comparison between two different unilateral mandibular partial denture designs retained by extra-coronal attachment. An In-Vitro Study

Article

Last updated: 01 Jan 2025

Subjects

-

Tags

Removable Prosthodontics

Abstract

Objectives: The objective of this study was to compare the strain induced around the abutments that support unilateral mandibular partial dentures with two different designs retained by extra-coronal attachment.
Methodology: This in-vitro study was performed on one epoxy resin Class II mandibular partially edentulous model. The last two abutments were prepared using tapered diamond stone with round end to receive a PFM bridge. The wax pattern of the bridge was then carved and the plastic pattern of the male part of the attachment was attached to the distal surface of the second premolar. The assembly was then casted, finished and polished and then cemented to the abutments. Two unilateral partial dentures with two different designs were then constructed on the model. The model was prepared around the abutments to receive the strain gauges. Force was then applied on the prosthesis using the universal testing machine and strain induced around the abutments was assessed.
Results: The results showed that the strain induced around the abutments supporting the unilateral removable porcelain bridge retained with extra-coronal attachment was higher than that induced when using a unilateral skeletal partial denture with combined denture base.
Conclusion: The material and design of the partial denture, whether acrylic resin or porcelain, had an effect on the strain induced around the abutment teeth. The unilateral skeletal partial denture with combined denture base might transfer less stresses to the supporting abutments than the unilateral removable porcelain bridge.

DOI

10.21608/edj.2022.127727.2024

Keywords

Class II Kennedy, unilateral partial denture, free end saddle, extra-coronal attachment

Authors

First Name

ahmed

Last Name

fayyad

MiddleName

-

Affiliation

Associate Professor, Prosthodontic Department Cairo University

Email

ahmed.fayyad@dentistry.cu.edu.eg

City

cairo

Orcid

0000-0002-6713-2150

Volume

68

Article Issue

3

Related Issue

35988

Issue Date

2022-07-01

Receive Date

2022-03-18

Publish Date

2022-07-01

Page Start

2,479

Page End

2,485

Print ISSN

0070-9484

Online ISSN

2090-2360

Link

https://edj.journals.ekb.eg/article_252854.html

Detail API

https://edj.journals.ekb.eg/service?article_code=252854

Order

3

Type

Original Article

Type Code

254

Publication Type

Journal

Publication Title

Egyptian Dental Journal

Publication Link

https://edj.journals.ekb.eg/

MainTitle

Comparison between two different unilateral mandibular partial denture designs retained by extra-coronal attachment. An In-Vitro Study

Details

Type

Article

Created At

22 Jan 2023