228891

Sequential Approach to Improve the Accuracy of 3D Printed Dental Implants Surgical Guides

Article

Last updated: 01 Jan 2025

Subjects

-

Tags

Oral and Maxillofacial Surgery

Abstract

Objective: To test the accuracy of implant sites drilled using 3D printed sleeve-free surgical guides made following a stepped approach directed to reduce the accumulative errors during the manufacturing process.
Material and methods: Twelve 3D printed surgical guides were constructed to plan twenty-four implants' drilling sites. The desktop 3D printer building platform was leveled. Layer normal exposure time and guide hole tolerance calibration were done. The predrilled casts were scanned, and the 3D models were exported as STL files. The surgical guides were designed, printed, and solidified according to the calibrated parameters. The drilled casts were scanned with the drill bit in the prepared site, and the exported STL post-drilling models were analyzed to measure the linear and the angular deviations of the drilled sites. The results were compared to the findings of previous studies.
Results: The mean and standard deviation of the coronal linear and angular deviation were 0.155 ± 0.095 mm and 1.129 ± 0.323°, respectively. The mean and standard deviation of the apical linear deviation at 5, 10, 15, and 20mm implant lengths were 0.246 ± 0.106 mm, 0.338 ± 0.125 mm, 0.429 ± 0.149 mm, and 0.520 ± 0.176 mm, respectively. The means and standard deviations were lower than that of the compared studies.
Conclusion: Addressing several errors during the manufacture of sleeve-free surgical guides reduces the degree of linear and angular deviation of the drilled implant sites.

DOI

10.21608/edj.2022.115586.1945

Keywords

3D LCD printers, Accuracy of 3D printed surgical guide, Layer Normal exposure time, Guide hole tolerance

Authors

First Name

Mohammed

Last Name

Al Kabany

MiddleName

Hassan

Affiliation

Department of Oral and Maxillofacial Surgery, Faculty of Dentistry, Cairo University, Cairo, Egypt

Email

mohhaseg2010@yahoo.com

City

-

Orcid

0000-0002-7401-2456

Volume

68

Article Issue

2

Related Issue

32788

Issue Date

2022-04-01

Receive Date

2022-01-10

Publish Date

2022-04-01

Page Start

1,367

Page End

1,376

Print ISSN

0070-9484

Online ISSN

2090-2360

Link

https://edj.journals.ekb.eg/article_228891.html

Detail API

https://edj.journals.ekb.eg/service?article_code=228891

Order

6

Type

Original Article

Type Code

254

Publication Type

Journal

Publication Title

Egyptian Dental Journal

Publication Link

https://edj.journals.ekb.eg/

MainTitle

Sequential Approach to Improve the Accuracy of 3D Printed Dental Implants Surgical Guides

Details

Type

Article

Created At

22 Jan 2023