Abstract

Aim:
In Vitro study was conducted to compare the retention of CM LOC and locator attachment systems in retaining mandibular overdenture upon simulation of insertion-removal cycles.
Materials Abd methods:
Ten complete dentures were fabricated on a Stone model representing a completely edentulous mandible that was obtained by making an impression for an edentulous patient. The stone model was duplicated using laboratory addition silicone after placing single implant analogue in the Medline using a dental surveyor. Then the mold was duplicated using epoxy resin. The prefabricated dentures were divided into two groups. Group was set to receive the CM LOC attachment and the other group was set to receive the ball attachment. Using a universal testing machine, the retention was measured at base line, 500, 1000, 1500, and 2000 insertion and removal cycles using ROBOTA chewing simulator, which represents (o,3,6,9,12) month; Considering that the patient will remove the denture 4 to 5 times a day
Results:
There was a statistically significant difference between the two types of attachments. The CM LOC attachment showed a higher statistically significant mean difference when compared to locator attachment after 1000 cycles (9 months). It was concluded that CM LOC appeared to have a favorable retention over the locator attachment in the first year with less serviceability.


DOI

10.21608/edj.2022.109753.1895

Keywords

Overdentures, overlay dentures, dental attachment, attachment system, implant retained and retention

Authors

First Name

Khaled

Last Name

Abdelwahab

MiddleName

-

Affiliation

Associate Professor, Department of Prosthodontics, Cairo University, New Giza University

Email

khaledaziz78@gmail.com

City

Giza

Orcid

-

Volume

68

Article Issue

1

Related Issue

30583

Issue Date

2022-01-01

Receive Date

2021-12-06

Publish Date

2022-01-01

Page Start

949

Page End

954

Print ISSN

0070-9484

Online ISSN

2090-2360

Link

https://edj.journals.ekb.eg/article_216689.html

Detail API

https://edj.journals.ekb.eg/service?article_code=216689

Order

34

Type

Original Article

Type Code

254

Publication Type

Journal

Publication Title

Egyptian Dental Journal

Publication Link

https://edj.journals.ekb.eg/

MainTitle

The Effect of Aging upon Retentive Characteristics of Two Different Stud Attachments In vitro Study

Details

Type

Article

Created At

22 Jan 2023