216664

Peri-implant strains with ball and telescopic attachments for implant supported maxillary overdentures. An invitro strain gauge analysis

Article

Last updated: 01 Jan 2025

Subjects

-

Tags

Removable Prosthodontics

Abstract

Purpose: This invitro study evaluates peri-implant strains with ball and telescopic attachments for implant supported maxillary overdentures.
Materials and methods: A model represent an edentulous maxillary ridge with 4 implants installed at both canine and second premolar areas was constructed. Experimental maxillary overdentures were fabricated and attached to the implants with rigid telescopic (TA, n=5), and ball (BA, n=5) attachments. Two strain gauges were bonded to the acrylic resin at buccal and palatal surfaces of each implant. Strains were measured during unilateral load application on the 1st molar region of the right (loading) side. Mann-Whitney test was used to compare microstrains between groups (TA, and BA), implant positions (canine and premolar implants) and strain gauge positions (buccal and palatal gauges on right and left sides).
Results: For all strain gauge positions of canine and premolar implants, TA showed significant higher microstrain than BA. For both groups, palatal loading side showed the highest microstrain for canine implants, and buccal loading side showed the highest microstrain for premolar implants. For palatal gauges on both sides, canine implants recorded significant higher strain than premolar implants. For buccal gauges on both sides, premolar implants recorded significant higher strain than canine implants.
Conclusion: Within limitation of this invitro study, it could be concluded that, ball attachments are recommended to retain maxillary implant overdenture than telescopic attachments as it were associated with reduced peri-implant strain.

DOI

10.21608/edj.2021.84705.1707

Keywords

TA = Rigid telescopic attachment, BA = Ball attachment, n = Number

Authors

First Name

Amr

Last Name

Emarah

MiddleName

-

Affiliation

Lecturer, Department of Removable Prosthodontics, Faculty of Dentistry, Fayoum University, Fayoum, Egypt

Email

amremarah@yahoo.com

City

-

Orcid

0009-0008-5856-6505

First Name

Shahinaz

Last Name

Mohamed

MiddleName

-

Affiliation

Assistant Professor, Department of Removable Prosthodontics, Faculty of Dentistry, Beni-Suef University, Egypt.

Email

shshinazsayed@gmail.com

City

Giza

Orcid

0000-0003-4468-5307

Volume

68

Article Issue

1

Related Issue

30583

Issue Date

2022-01-01

Receive Date

2021-07-08

Publish Date

2022-01-01

Page Start

697

Page End

706

Print ISSN

0070-9484

Online ISSN

2090-2360

Link

https://edj.journals.ekb.eg/article_216664.html

Detail API

https://edj.journals.ekb.eg/service?article_code=216664

Order

12

Type

Original Article

Type Code

254

Publication Type

Journal

Publication Title

Egyptian Dental Journal

Publication Link

https://edj.journals.ekb.eg/

MainTitle

Peri-implant strains with ball and telescopic attachments for implant supported maxillary overdentures. An invitro strain gauge analysis

Details

Type

Article

Created At

22 Jan 2023